Skip to content

Author

Kailash Kharat

1 paper indexed here

We haven’t gathered this author’s papers yet. Follow them and we’ll fetch their work.

Not the right person? Other researchers publish under this name.

Open access Jul 2026

Vision Transformer Outperforms CNN Architectures in Binary Skin Lesion Classification: An Eight-Model Controlled Deep Learning Study

Skin cancer is one of the life-threatening malignancies in the world, timely detection of which is directly proportional to the survival of patients. Traditional dermoscopic diagnosis suffers inter-observer variability, lack of specialists and is not scalable in resource limited healthcare environments. The end-to-end hierarchical feature learning provided by deep learning is a transformative solution to the learned dermoscopic image corpora. The paper empirically comparatively examines eight binary skin lesion classifiers benign versus malignant of a dataset of 2,637 training images, and 661 held out test images. The assessed architectures are located on a wide design range a custom CNN trained using fresh data, two ResNet18 transfer learning pipelines, DenseNet121, MobileNetV3-Large, ViT-Small/16 (ImageNet-21K), ConvNeXt-Tiny (ImageNet-12K) and EfficientNetV2-S (ImageNet-21K). All the models are trained with the same conditions involving stratified splitting, Weighted Random Sampler, two-stage fine tuning with discriminative learning rates, Automatic Mixed Precision, and early stopping. It is evaluated using six metrics accuracy, per-class precision, recall, F1-score, ROC-AUC, and PR-AUC. The highest test accuracy (91.53) and macro-F1 (0.907) is attained with EfficientNetV2-S. ViT-Small/16 has the best ROC-AUC (0.9723) and PR-AUC (0.9699), which proves the effectiveness of Vision Transformer in threshold-free probabilistic discrimination the clinically decisive measure in screening applications. The three contemporary timm-based models have consistently reached ROC-AUC 0.95 and above, but the legacy CNN models are at 0.56 even though the legacy CNN models are at competitive accuracy of 89-90%. MobileNetV3-Large yields a false negative rate of 61 (20% miss rate), which highlights the clinical risk of aggressive model compression. The findings simplify the selection of the model in clinical studies in implementing dermoscopy, suggesting that ViT-Small/16 should be used as a probabilistic-ranked malignancy screening model, and EfficientNetV2-S should be used as a fixed threshold binary triage model in a telemedicine system.

Bharti G. Gadge, Vikul J. Pawar, Vinod Damdhar et al. · 0 citations