Evaluation of Computer‐aided Detection for Identifying Missed Gastric Cancer After Endoscopic Submucosal Dissection
No significant difference in sensitivity was observed between CADe and endoscopist detection for MGCs after ESD, and the absolute sensitivity remained low, so further improvements are needed before clinical implementation of CADe as a double‐checking tool.