Skip to content

Author

Paolo Nava

2 papers indexed here

We haven’t gathered this author’s papers yet. Follow them and we’ll fetch their work.

Not the right person? Other researchers publish under this name.

Open access Jul 2026

Accuracy of scannable anatomic healing abutments for implant-supported crown and fixed partial prostheses: An in vitro comparison with conventional scan bodies.

STATEMENT OF PROBLEM Accurate digital implant scanning is critical for the fit, function, and biological stability of implant-supported restorations. Anatomic scannable healing abutments (AHAs) have been proposed as an alternative to conventional scan bodies (SBs) to simplify digital workflows and facilitate the development of an adequate emergence profile. However, their accuracy in crown and short-span fixed dental prosthesis scenarios remains insufficiently investigated. PURPOSE The purpose of this in vitro study was to compare the trueness and precision of implant position detection obtained using AHAs versus SBs in single-crown and short-span fixed dental prosthesis configurations. MATERIAL AND METHODS Two partially edentulous maxillary models were digitally designed and 3-dimensionally (3D) printed: 1 with a single molar edentulous site and 1 with a 3-tooth posterior edentulous span. Implant analogs were placed in the models to simulate a single implant site and a 3-unit implant fixed dental prosthesis site. AHAs (test group) or SBs (control group) were connected to the analogs. A desktop scanner was used to obtain baseline scans for each group, while 15 consecutive intraoral scans per group were acquired using an intraoral scanner. Linear (mesiodistal, buccolingual, coronoapical), angular, and overall 3D deviations at the implant platform center were calculated and analyzed using the t test and Mann-Whitney U test. RESULTS For the single-crown model, AHAs demonstrated significantly better mean 3D trueness than SBs (20 µm and 74 µm; P<.001), as well as better angular deviation (0.11 degrees and 0.44 degrees; P<.001). Precision was also better for AHAs, with a mean 3D deviation of 10 ±5 µm compared with 67 ±37 µm for SBs (P<.001). In the 3-unit fixed dental prosthesis model, AHAs consistently showed better trueness and precision at both premolar and molar positions. At the molar site, mean 3D trueness was 24 µm for AHAs versus 103 µm for SBs (P<.001), and mean 3D precision was 22 ±9 µm versus 79 ±54 µm (P<.001). CONCLUSIONS AHAs demonstrated significantly higher trueness and precision than SBs for implant position detection in single-crown and short-span fixed dental prosthesis scenarios.

Paolo Nava, Carlo Nava, David Dunbar et al. · 0 citations
Case report Open access Jul 2026

Bone stability after regenerative peri-implantitis treatment: A 10-year follow-up case study.

BACKGROUND Peri-implantitis poses a significant challenge to implant longevity, leading to progressive bone loss and potential implant failure. While reconstructive surgery has been proven effective in regenerating peri-implant tissues, the long-term stability of the regenerated tissues and the impact of supportive peri-implant care (SPIC) on bone levels remains underexplored. This case study presents a 10-year follow-up of a patient treated with reconstructive surgery for peri-implantitis and enrolled in a structured maintenance program. METHODS A 68-year-old male with a failing implant in the mandibular right first molar was treated using a reconstructive approach involving surface decontamination, particulate bone grafts, and an acellular dermal matrix as a barrier. Three re-entry procedures were performed over a 10-year period: at 9 months for the second stage of the two-step GBR procedure and at 8 and 10 years for implant placement to replace fractured teeth. These interventions allowed for direct clinical and radiographic assessment of bone-level changes. RESULTS At 9 months, bone regeneration was observed with minor residual dehiscences. After 8 years, bone remodeling and crestal bone gain on the lingual aspect were noted in the absence of further surgical interventions. At 10 years, radiographic evaluations confirmed minimal changes in marginal bone levels. CONCLUSIONS The presented two-stage regenerative approach successfully restored peri-implant health and function over time while minimizing the patient's financial burden. The three re-entry procedures provided direct clinical evidence of bone regeneration and demonstrated the positive impact of effective maintenance therapy on marginal bone levels and their long-term stability. KEY POINTS The described regenerative treatment for peri-implantitis may ensure long-term satisfactory outcomes. Supportive peri-implant care (SPIC) is effective in preventing disease recurrence and may improve crestal bone levels over time. PLAIN LANGUAGE SUMMARY This study presents the case of a 68-year-old patient with a failing dental implant due to peri-implantitis. The implant was treated by thoroughly cleaning its surface, placing bone grafts, and using a protective membrane to regenerate bone around the fixture and obtain disease resolution. The patient returned for three follow-up surgeries over 10 years, providing a unique opportunity to directly examine bone stability around the implant. Direct observations revealed that the bone graft healed well within the first 9 months, and the regenerated peri-implant bone remained stable with minimal changes for a decade. Regular check-ups and cleanings also helped prevent disease recurrence and further bone loss. By saving the existing implant, the patient avoided the extra expenses of removing and replacing it. Overall, these results suggest that a regenerative surgical approach, combined with structured maintenance care, can help obtain disease resolution and maintain stable long-term outcomes. This can improve comfort and function while reducing costs for patients.

S. Parma-Benfenati, M. Roncati, Lucrezia Parma-Benfenati et al. · 0 citations