Skip to content

Author

Sathishkumar Chinnapaiyan

1 paper indexed here

We haven’t gathered this author’s papers yet. Follow them and we’ll fetch their work.

Not the right person? Other researchers publish under this name.

Jul 2026

Highly Sensitive LIG-Derived Electrochemical Biosensor for Simultaneous Detection of Aβ42/Aβ40 Ratio in Alzheimer’s Early Diagnosis

Alzheimer’s disease (AD) is a progressive neurodegenerative disorder characterized by the accumulation of amyloid-beta (Aβ) plaques in the brain. Recent clinical studies indicate that the ratio of Aβ42 to Aβ40 in blood plasma is a more reliable biomarker for early AD screening than individual peptide concentrations, as it reflects the brain's Aβ sequestration. However, detecting these biomarkers in blood remains challenging due to their ultra-low abundance and the structural similarity between Aβ42 and Aβ40. In this work, we developed an electrochemical biosensor using laser-induced graphene (LIG) electrodes, fabricated via one-step CO 2 laser scribing on polyimide. To optimize the interface for antibody immobilization, a low-damage plasma treatment (LDPT) was strategically employed to introduce nitrogen-containing functional groups (e.g., amine groups) onto the LIG surface. This plasma-assisted modification creates highly reactive sites that facilitate the stable and high-density covalent bonding of specific Aβ42 and Aβ40 antibodies via their carboxyl groups, ensuring a robust bio-interface without compromising the structural integrity of the graphene lattice. The resulting LIG-based biosensors demonstrated exceptional sensitivity, achieving a limit of detection (LOD) at sub-picomolar concentrations. To validate the clinical diagnostic potential, we examined the sensor's specificity by preparing a series of samples with predefined Aβ42/Aβ40 concentration ratios. These samples were tested on Aβ42 and Aβ40-antibody-modified sensors, respectively. The results indicated that the detected concentration ratios were highly consistent with the known concentrations, confirming the platform's high fidelity and cross-reactivity resistance for the precise determination of the Aβ42 to Aβ40 ratio in complex analytical scenarios. By leveraging LDPT for surface functionalization, we have developed a robust and sensitive LIG-based electrochemical biosensing platform of electrochemical biosensors. This approach provides a scalable and cost-effective solution for the simultaneous detection of Aβ biomarkers, supporting the development of portable point-of-care devices for early Alzheimer’s intervention.

Sathishkumar Chinnapaiyan, Yu-Chen Hong, Chi-Hsien Huang · 0 citations