2026· E3S Web of Conferences· Vol 729, pp. 01001· 0 citations· 5 references
Abstract
The increasing global energy demand and large-scale renewable energy resources integration have intensified concerns over power system stability, particularly at extra-high voltage (EHV) transmission level. Shunt capacitor banks are widely employed to enhance voltage stability, but their energization often introduces severe transient overvoltage and inrush currents that threaten equipment reliability and grid security. This paper investigates the application of synchronous switching using the Point-on-Wave (PoW) technique as a mitigation strategy for transient disturbances during capacitor bank energization. A two-stage methodology was adopted, combining MATLAB/Simulink-based transient modelling with field implementation at Eskom’s 400 kV Delphi Transmission Substation. The simulation results demonstrated that uncontrolled switching produced peak disturbances of 1.04 kA and 479 kV, corresponding to ±480% and 22% transient elevation above nominal levels. By contrast, PoW switching at the zero-crossing reduced peak transients to 539 A and 412 kV, representing reductions of approximately 51% in current and 15% in voltage. Field experiments using a Schneider RPH2 PoW relay integrated with a GE C70 protection relay further validated these results, confirming significant reductions in inrush stress, transient duration, and breaker wear. Beyond technical validation, the study highlights operational benefits including improved equipment lifetime, lower maintenance costs, and enhanced system reliability, critical for renewable-rich and stability-constrained power systems. The findings establish PoW-based switching as a practical and scalable solution for transient mitigation in modern EHV grids.
The increasing penetration of distributed energy resources (DERs) has significantly altered the dynamic behavior of emerging power systems, particularly during severe voltage disturbances. Unlike synchronous generators, inverter-based DERs are inherently current-limited and rely on phase-locked loop (PLL) strategy for...
Ashkan Khashei, R. Razzaghi, M. G. Dozein· 2026 International Conferenc...· 0 citations
The increasing complexity of modern electrical networks, driven by the expansion of transmission networks along with the increasing penetration of renewable-based generation, has intensified concerns regarding voltage control performance and rotor-angle stability. Flexible AC transmission system (FACTS) technology, par...
Makhlouf Chouki, H. Zaimen, H. Belila· International Journal of App...· 0 citations
With the growth of emerging data centers and electric vehicles, DC power distribution and hybrid microgrids are attracting growing attention. Due to the lack of a natural zero-crossing point in DC current, reliable DC fault protection is critical. This paper introduces a transient-minimized fault protection scheme util...
Renewable energy integration increases operating variability and tightens voltage and reactive-power control requirements, which elevates the importance of reliable reactive-power management and robust switching practices in transmission networks. In this paper, renewable integration is treated as an operational contex...
V. Kuchanskyy, Y. Tugai, V. Kuznetsov et al.· Vidnovluvana energetika· 0 citations
The virtual synchronous generator (VSG) is an effective grid-forming control technique for power converters that are required to provide inertia, frequency support, and voltage support. This work focuses on balanced three-phase operation under symmetrical voltage sags, where a three-phase grid-forming converter may sim...
Jia-Wei Liu, Cheng-Bo Zhang, Qi Wang et al.· Energies· 0 citations
With increasing renewable penetration, virtual synchronous generators (VSGs) have become an important solution for stabilizing converter-interfaced renewable generation because of their inertia support and grid-forming capability. However, under weak-grid voltage sag conditions, the transient synchronizing stability of...
Gang Li, Hao-Zheng Xu, Jia-Hui Wang et al.· Engineering Research Express· 0 citations