The problem of electrical and electronic equipment immunity to high- voltage short- duration power supply surges, specifically high- energy microsecond surge disturbances, is considered. The causes of microsecond surge occurrence, with amplitudes reaching 2 kV and higher, are shown. A review of various methods and means of equipment surge protection has been conducted, demonstrating that the most effective approach is the use of two- terminal devices with highly non- linear current-voltage characteristics: varistors, suppressors, and gas discharge tubes. The operating principles of these two- terminal devices were analyzed, showing that standard direct connection at the equipment power input is insufficiently effective when the power network impedance is low at frequencies corresponding to the surge duration. An L -shaped connection scheme incorporating an LR -circuit alongside a two - terminal non-linear device is proposed. The obtained results indicate that this topology reduces the surge amplitude at the power input by 1.5 times more than a standalone non-linear device, even under low power grid impedance at high frequencies. The addition of a multi-stage π-type low-pass filter allows for reducing the surge amplitude by 20 times or more compared to conventional varistor or suppressor arrangements.
Ensuring a reliable power supply for a production process is impossible without the uninterrupted operation of power system components. The current trend toward increasing power consumption in the electrical grid infrastructure of metallurgical enterprises increases the probability of higher short-circuit currents, whi...
S. Trofimova, Yury S. Sergeev, S. Platov et al.· Vestnik of Nosov Magnitogors...· 0 citations
High- and ultra-high-voltage overhead power lines are critical for
maintaining a reliable electricity supply to industrial consumers and
regional power systems in the Republic of Kazakhstan. The country’s
large geographic extent, coupled with harsh and highly variable climatic
conditions, imposes additional demands...
N. Kydyrov, V. Kaverin, A. Yurchenko· Bulletin of Toraighyrov Univ...· 0 citations
This paper examines the problem of increasing the sensitivity of backup protection systems, specifically long-range backup protection systems (LRPS), at 110-220 kV branch substations (BSS) with relatively low-power power trans-formers (6.3-16 MVA). Short-circuit currents (SC) during faults on the low-voltage (LV) side...
A. V. Ukraintsev, V. Nagay, I. Nagay et al.· Известия высших учебных заве...· 0 citations
Conventional applications of vacuum interrupters cover a broad operating frequency range from 60 Hz down to 16.7 Hz, as typically found in power networks and railway electrical systems. With the increasing integration of alternative power sources and the growing complexity of decentralized power networks, new requireme...
D. Gentsch, A. Lawall, S. Gortschakow· IEEE Transactions on Plasma...· 0 citations
External steep-front transient overvoltages may introduce high-frequency electromagnetic disturbances into modular multilevel converter-based high-voltage direct current (MMC-HVDC) systems, resulting in additional transient voltage stresses on converter valves and their sub-modules. This paper investigates the propagat...
Qian Li, Zhi-Chao Yang, Jian Ji et al.· Energies· 0 citations
Driven by the “dual carbon” goals, the large-scale application of renewable power generation, DC distribution networks, and energy storage systems has increasingly highlighted the short-circuit protection challenges in low-voltage DC (LVDC) systems. LVDC faults are characterized by rapidly rising fault currents and the...