Field-Validated Induced-Voltage Testing and Power-Supply Capacity Calibration for Converter Transformer Systems Considering Parasitic Capacitance

Aug 2026 · Electronics · Vol 15, pp. 3560 · 0 citations · 13 references

Abstract

Field voltage testing after the maintenance of large converter transformers requires high-voltage response verification while preserving the restored equipment boundary. However, conventional direct voltage application on the grid side usually requires the disconnection of high-voltage leads and auxiliary devices, which may alter the original electrical boundary and increase field disturbance. To address this issue, this study develops an integrated framework with three core contributions: a minimal-lead-disconnection induced-voltage testing topology, a boundary-specific engineering-equivalent parasitic-capacitance model, and a terminal-referred phasor-based power-supply capacity-calibration method. Under the proposed testing topology, single-phase power-frequency excitation is applied on the valve side, and the induced-voltage response is established at the grid-side bushings while some of the restored auxiliary-equipment connections are retained. Considering the parasitic capacitance introduced by valve towers, tubular busbars, grading fittings, and grid-side auxiliary devices under the minimal-lead-disconnection boundary, an engineering equivalent model for extracting the valve-side stray capacitance is developed based on quasi-static electric field theory, geometric-envelope dimensional reduction, and conformal-mapping-based edge correction. The grid-side equivalent capacitance is further obtained using equipment parameters. On this basis, the induced-voltage distribution under the interconnection of multiple converter transformers is analyzed, and a power-supply capacity-calibration method considering the phasor relationship between inductive excitation current and capacitive current is established. Pre-test calculations yield a valve-side stray capacitance of 0.96 nF and a grid-side equivalent capacitance of 1.27 nF. When the grid-side induced voltage of phase C reaches 9.90 kV, the induced voltages of phases A and B are 4.56 kV and 5.14 kV, respectively, while the apparent power calculated from the field-measured RMS voltage and current is 1.34 kVA. The results verify the effectiveness of the proposed method for low-disturbance field testing and portable test-power-supply configuration.

Read PDF

Similar papers

Conference Sep 2026

Voltage-Only Modal Diagnostics of Internal Short-Circuit Faults in Inverter-Cable-Machine Systems Using Transient Response Analysis

Wide-bandgap (WBG) inverter drives impose repetitive high-frequency voltage stress, accelerating insulation degradation and increasing the probability of short-circuit faults in cables and machine windings. However, existing online diagnostic approaches face significant deployment barriers due to their sensitivity to e...

Yue Yu, Hu-Jun Peng, S. Steentjes · 0 citations
Sep 2026

Performance study of a DC electronic voltage transformer with passive temperature error correction capability

This study aims to address the temperature-dependent error of the primary voltage divider (PVD) in direct current electronic voltage transformers (DC-EVT). Taking full advantage of the superior properties of optical fiber sensors such as passivity, light weight and excellent insulation, a high-resolution polarizati...

Jun Zhao, Yushi Wu, Yun-Tian Zhang et al. · 0 citations
Conference Open access Sep 2026

Design of dynamic and thermal stability test system for UHV switchgear based on 330kV grid power supply

To meet the low-voltage, high-current, and long-duration requirements of thermal and dynamic stability tests for UHV disconnectors and earthing switches, this paper proposes a two-stage step-down test system powered by a 330 kV grid. The system employs a 12.5 MVA transformer (330 kV/35 kV) and a 90 MVA short-time-rated...

Zhi-Lin Kang, Yu-Lin Kang, Jian-Zhen An et al. · 0 citations
Open access Aug 2026

Enhancement of Renewable Power System Protection Reliability Using a Superconducting Fault Current Limiting Circuit Breaker (SFCL-CB)

The proliferation of inverter-based resources (IBRs) and energy storage systems in power grids has led to a decline in the short-circuit ratio (SCR) and reduced fault current magnitudes, compromising the reliability of conventional overcurrent relays (OCRs) and creating protection blind zones. To resolve these vulnerab...

Sangjae Choi, Sung-Hun Lim · 0 citations
Open access 2026

An Offline Condition Monitoring Method for the DC-Link Capacitors in Power Electronic Converters

Electrolytic capacitors are widely used as DC-link components in power electronic converters such as switched-mode power supplies (SMPSs) and inverters; however, they are also among the most vulnerable components, and their capacitance degradation critically affects overall system lifetime. Condition monitoring is chal...

Xue-Li Zhu, Ya-Jie Huang, Yue-Peng Zhang et al. · 0 citations
Open access Sep 2026

Condition assessment of medium voltage cable insulation using leakage current and phase-resolved partial discharge

Reliable operation of medium-voltage distribution networks critically depends on the integrity of cross-linked polyethylene (XLPE) insulated cables. This paper proposes a diagnostic methodology that integrates leakage current (LC) measurement with phase-resolved partial discharge (PRPD) analysis to assess cable insulat...

K. Janprom, Sittadach Morkmechai, Natchanun Prainetr et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.