Jul 2026· Engineering Research Express· Vol 8, pp. 155403· 0 citations
Physics
Abstract
When a power transformer subjected to transient over-voltages containing different harmonic components, the frequency components of over-voltages are coupled with the inherent electrical frequency of the transformer winding, which can induce high-amplitude resonant over-voltages in the winding and thus lead to transformer insulation failures. To analyze the electrical resonance characteristics of transformer windings, this paper establishes an equivalent model of transformer windings with reference to the actual transformer structure, and calculates the time-domain and frequency-domain distributions of transformer winding voltages. Furthermore, a test model of a real three-phase transformer is constructed, with measurement wires embedded at different positions of the windings. Experimental tests are conducted to investigate the electrical resonance characteristics of the transformer windings, verifying the effectiveness of the established equivalent model. Finally, based on the equivalent model, the effects of winding structure, number of turns per disk, wire thickness, and oil duct width on the winding resonance characteristics are analyzed.
As a critical component of power systems, the operational status of power transformers directly affects the safety and reliability of the power grid. Addressing the challenge that traditional methods struggle to achieve online monitoring of winding deformation faults, this paper proposes a novel method for online detec...
Lai-Hong Wei· European Conference on Elect...· 0 citations
Aim. To develop a computational equivalent circuit for a three-phase transformer with a fundamentally new design configuration and a secondary-winding voltage stabilization function as the traction current of the supply substation varies.
Materials and Methods. Elements of electric circuit and electromagnetic field th...
A. Tkachuk· Modern Transportation System...· 0 citations
Internal temperature monitoring is an important approach for assessing the operating condition of power transformers. Temperature-rise characteristics not only indicate faults such as inter-turn short circuits but also indirectly reflect the diffusion and transport behaviors of characteristic dissolved gases within the...
Zi-Fan Zhao, Shan Yu, Shi-Man Lin et al.· Energies· 0 citations
Under long-term high-load operating conditions, electric field concentration and magnetic flux leakage in transformers can adversely affect operational stability. To address the insufficient attention paid to the coordinated optimization of electric and magnetic fields in existing studies, this paper investigates the e...
Limin Chen, Shou-Ye Li, Zeng-Xiang Zhang et al.· Journal of Physics, Conferen...· 0 citations
The main scope of this research was to complete and validate the analysis of stator winding topologies of six-phase AC machines using the winding quality factor by determining fault tolerance and validating it through experimental tests. This paper proposes a unified and practical methodology for evaluating the perform...
P. Todos, Ghenadie Tertea, I. Nucă et al.· Technologies· 0 citations
Sweep Frequency Response Analysis (SFRA) serves as a highly sensitive diagnostic technique for identifying mechanical deformations within power transformer windings. The inherent magnetic and capacitive inter-winding couplings in transformers mean that a fault localized to a single winding can propagate detectable anom...
M. Gojiya, M. Solanki, A. Parmar et al.· ITEGAM- Journal of Engineeri...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.