Jul 2026· JET (Journal of Electrical Technology)· Vol 11, pp. 67-73· 0 citations· 24 references
Abstract
Insulators are vital components in electrical power transmission systems, yet they are susceptible to degradation caused by electrical and environmental stresses. This study aims to analyze Partial Discharge (PD) characteristics in glass and porcelain insulators as an early indicator of insulation failure. Experimental testing involved a step-wise increase in AC voltage from 5 kV to 20 kV, alongside simulations of extreme conditions using exposure to a flame to trigger flashover phenomena. Discharge activity was detected using a PMDT PDetector instrument in accordance with the IEC 60270 standard. The results indicate that within the 5 – 15 kV range, the insulators exhibited stable performance with PD magnitudes below 20 dB. However, at 20 kV, a significant anomaly was observed in the glass insulator, characterized by a magnitude spike reaching 174 dB across the 360° phase, signaling a transition toward total failure. Phase-Resolved Partial Discharge (PRPD) pattern analysis demonstrated that thermal stress drastically lowers the air breakdown voltage threshold near the insulator surface. The study concludes that high-frequency detection methods are highly effective for the non-intrusive monitoring of insulation conditions, thereby helping to prevent catastrophic failures in electric power systems.
RELEVANCE of the study is to obtain new experimental data to improve the reliability of electrical equipment diagnostics using partial discharge (PD) measurements.
THE PURPOSE. To determine the characteristics of partial discharges occurring within a single air defect located in a solid insulation.
METHODS. To achiev...
F. Nyetereye, A. E. Usachev, S. Boboev et al.· Power engineering (Barringto...· 0 citations
This study investigates the impact of creepage distance and insulator geometry on the AC flashover voltage (FOV) and parallel-discharge characteristics of flat-glass insulator models under uniform pollution conditions. Experimental tests were conducted using a plane-plane electrode configuration with pollution conducti...
Samia Satta, Hasna Boulanouar, Meriem Messaoudi et al.· Journal of applied engineeri...· 0 citations
The reliability and efficiency of high-voltage power systems are critically dependent on the
performance of insulating materials, which prevent electrical failures by withstanding high
voltages. Insulation breakdown occurs when the dielectric strength of a material is exceeded,
leading to system faults and reduced o...
L. Dumkhana· WORLD JOURNAL OF INNOVATION...· 0 citations
This paper investigates the breakdown characteristics and environment-matched detection of multilayer ethylene vinyl acetate (EVA) and polytetrafluoroethylene (PTFE) insulation structures for live-line protective equipment. Different from conventional material breakdown tests under a single medium, this work focuses on...
Run-Tao Jing, Chun-Ming Wei, P. Tang et al.· Journal of Physics, Conferen...· 0 citations
Phenomenon of concurrent external discharges and plasma expansion can occur in practical coaxial dielectric barrier discharge (DBD) systems, yet their impact on electrical diagnostics and discharge behavior remains insufficiently understood. To investigate these effects, a coaxial atmospheric-pressure air DBD operated...
Raif Hamzah, L. Lim, H. Wante et al.· Physica Scripta· 0 citations
Reliable operation of medium-voltage distribution networks critically depends on the integrity of cross-linked polyethylene (XLPE) insulated cables. This paper proposes a diagnostic methodology that integrates leakage current (LC) measurement with phase-resolved partial discharge (PRPD) analysis to assess cable insulat...
K. Janprom, Sittadach Morkmechai, Natchanun Prainetr et al.· International Journal of App...· 0 citations