Skip to content
Open access

Identification of Partial Discharge Phenomena in Glass Insulator Testing Using HFCT

Jul 2026 · JET (Journal of Electrical Technology) · Vol 11, pp. 67-73 · 0 citations · 24 references

Abstract

Insulators are vital components in electrical power transmission systems, yet they are susceptible to degradation caused by electrical and environmental stresses. This study aims to analyze Partial Discharge (PD) characteristics in glass and porcelain insulators as an early indicator of insulation failure. Experimental testing involved a step-wise increase in AC voltage from 5 kV to 20 kV, alongside simulations of extreme conditions using exposure to a flame to trigger flashover phenomena. Discharge activity was detected using a PMDT PDetector instrument in accordance with the IEC 60270 standard. The results indicate that within the 5 – 15 kV range, the insulators exhibited stable performance with PD magnitudes below 20 dB. However, at 20 kV, a significant anomaly was observed in the glass insulator, characterized by a magnitude spike reaching 174 dB across the 360° phase, signaling a transition toward total failure. Phase-Resolved Partial Discharge (PRPD) pattern analysis demonstrated that thermal stress drastically lowers the air breakdown voltage threshold near the insulator surface. The study concludes that high-frequency detection methods are highly effective for the non-intrusive monitoring of insulation conditions, thereby helping to prevent catastrophic failures in electric power systems.

Read PDF

Similar papers

Open access Sep 2026

Partial discharges in gas insulation defects

RELEVANCE of the study is to obtain new experimental data to improve the reliability of electrical equipment diagnostics using partial discharge (PD) measurements. THE PURPOSE. To determine the characteristics of partial discharges occurring within a single air defect located in a solid insulation. METHODS. To achiev...

F. Nyetereye, A. E. Usachev, S. Boboev et al. · 0 citations
Open access Sep 2026

Influence of Creepage Distance and Pollution Severity on Flashover Voltage and Parallel Discharge Mechanisms in Glass Insulators

This study investigates the impact of creepage distance and insulator geometry on the AC flashover voltage (FOV) and parallel-discharge characteristics of flat-glass insulator models under uniform pollution conditions. Experimental tests were conducted using a plane-plane electrode configuration with pollution conducti...

Samia Satta, Hasna Boulanouar, Meriem Messaoudi et al. · 0 citations
Open access Sep 2026

Insulation Breakdown Strength Under AC and DC Stress Using Different Dielectric Materials: An Empirical Synthesis

The reliability and efficiency of high-voltage power systems are critically dependent on the performance of insulating materials, which prevent electrical failures by withstanding high voltages. Insulation breakdown occurs when the dielectric strength of a material is exceeded, leading to system faults and reduced o...

L. Dumkhana · 0 citations
Conference Open access Sep 2026

Breakdown characteristic differences and environment-matched detection of multilayer polymer insulation structures

This paper investigates the breakdown characteristics and environment-matched detection of multilayer ethylene vinyl acetate (EVA) and polytetrafluoroethylene (PTFE) insulation structures for live-line protective equipment. Different from conventional material breakdown tests under a single medium, this work focuses on...

Run-Tao Jing, Chun-Ming Wei, P. Tang et al. · 0 citations
Open access Sep 2026

Hidden influence of external discharges and plasma expansion on electrical diagnostics and microdischarge behavior in coaxial air dielectric barrier discharges

Phenomenon of concurrent external discharges and plasma expansion can occur in practical coaxial dielectric barrier discharge (DBD) systems, yet their impact on electrical diagnostics and discharge behavior remains insufficiently understood. To investigate these effects, a coaxial atmospheric-pressure air DBD operated...

Raif Hamzah, L. Lim, H. Wante et al. · 0 citations
Open access Sep 2026

Condition assessment of medium voltage cable insulation using leakage current and phase-resolved partial discharge

Reliable operation of medium-voltage distribution networks critically depends on the integrity of cross-linked polyethylene (XLPE) insulated cables. This paper proposes a diagnostic methodology that integrates leakage current (LC) measurement with phase-resolved partial discharge (PRPD) analysis to assess cable insulat...

K. Janprom, Sittadach Morkmechai, Natchanun Prainetr et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.