Aug 2026· Journal of Electrical Engineering and Informatics· Vol 4, pp. 30-40· 0 citations
Abstract
The industrial sector's need for reliable electrical energy demands a power generation system capable of maintaining voltage and reactive power stability. Synchronous generators play a crucial role in maintaining power quality by regulating excitation current, which influences output voltage and reactive power. This study aims to analyze the effect of excitation current on the output voltage and reactive power of a generator at PT. PELINDO New Makassar Container Terminal and to determine the most stable operating conditions. A descriptive quantitative research method was employed, utilizing a simulation approach with Electrical Transient and Analysis Program (ETAP) software and validating the results against real-time data from generator log sheets. Excitation current was varied within a range of 70% to 110% of the nominal value (2.6 A). Simulation results indicate that increasing the excitation current from 1.82 A to 2.86 A caused the output voltage to rise from 280 V to 440 V and the reactive power to increase from 187.5 kVAR to 200.5 kVAR. Regression and correlation analyses revealed a very strong relationship between excitation current and both output voltage (r = 0.999) and reactive power (r = 0.998). Real-time data also showed a very strong correlation between excitation current and output voltage (r = 0.999), whereas the relationship with reactive power was relatively weak (r = 0.186), influenced by the operation of the Automatic Voltage Regulator (AVR), load fluctuations, and the contribution of capacitor banks. The novelty of this research lies in integrating ETAP simulation results with real-time generator data validation—using regression and correlation analyses—to reveal the distinct characteristics of how excitation current affects output voltage and reactive power under actual operating conditions influenced by the AVR, load changes, and capacitor banks. This study concludes that excitation current directly affects the generator's output voltage and contributes to changes in reactive power; therefore, precise regulation of the excitation current is necessary to maintain the operational stability of the electrical system.
The integration of D-STATCOM into the transmission system enables reactive power compensation in the SEP, with the aim of stabilizing voltage and reducing active power losses. Diverging from conventional models that depend on simplified linear assumptions, this work integrates full non-linear power-flow equations; thes...
J. Monzalve-Pacheco, M. León-segovia, A. León-Segovia et al.· WSEAS Transactions on power...· 0 citations
The proliferation of non-linear loads in modern electrical systems has intensified the degradation of Power Quality (PQ), leading to technical and economic impacts ranging from equipment overheating to significant financial losses. Given the need for continuous monitoring in compliance with current regulations, such as...
Antônio Lima, T. Weber· 2026 10th International Symp...· 0 citations
Loss-of-excitation faults are a common fault form of pumped storage units that can threaten both unit safety and grid stability. However, the traditional loss-of-excitation protection based on the impedance principle may exhibit delayed operation or even fail to operate in the case of partial loss of excitation or loss...
Wen-Feng Lin, Yong Li, Bin Lu et al.· Energies· 0 citations
Non-sinusoidal operating conditions are frequently present in modern power systems and can adversely affect the normal operation and performance of industrial equipment connected to the electrical grid. This paper presents a method for evaluating the relationship between the harmonic weights of voltage and current and...
P. Andrei, S. Deleanu, Marilena Stănculescu et al.· Energies· 0 citations
Introduction. In 6-10 kV electrical networks with high-power induction motors, emergency modes accompanied by voltage sags, motor starts, and self-starts significantly reduce the reliability of power supply. The selection of the Automatic Transfer Switch (ATS) operating speed is of particular importance, as the superpo...
B. A. Korobeinikov, A. M. Oppakhodzhaev, D. I. Sidorov· Вестник Северо-Кавказского ф...· 0 citations
This study was conducted to enhance voltage stability within the 33kV Trans-Amadi Industrial
Power Transmission Network using an optimized Dynamic Voltage Restorer (DVR) under a
quantitative simulation-based research design. Data required for modelling voltage sags, swells,
harmonic distortion, reactive imbalance an...
Samuel Kehinde Adegun· International Journal of Eng...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.