Skip to content
Open access

Seamless vital sign monitoring with fiber optic sensing technology: validating the sitting SMART MAT for community health in static and mobile conditions

Jul 2026 · Frontiers in Physiology · Vol 17 · 0 citations · 48 references
Medicine

TL;DR

The current SMART MAT is a viable, integrated multimodal platform that reduces immobility-related complications and demonstrates high feasibility for continuous, real-world monitoring.

Abstract

Background Continuous vital sign monitoring is critical but often labor-intensive. Fiberoptic technologies, like the SMART MAT, offer non-invasive assessment. Adapting this for a seated posture addresses clinical needs by promoting safe patient mobilization and reducing complications associated with prolonged bed rest. Objectives To validate the accuracy of the sitting SMART MAT for respiratory rate (RR), heart rate (HR), oxygen saturation (SpO2), and systolic and diastolic blood pressure (SBP/DBP) against established clinical reference standards. Methods This cross-sectional study compared sitting SMART MAT readings with clinical reference measurements under stationary and mobile wheelchair conditions. Accuracy was assessed using Mean Absolute Error (MAE), Mean Absolute Percentage Error (MAPE), Bland-Altman Limits of Agreement (LoA), repeated-measures ANOVA, and effect size. Results Data from 130 participants were analyzed. HR readings demonstrated high accuracy (MAE = 3.67–4.81 bpm) with tight LoA. RR error was minimal (MAE = 2.85–2.86 breaths/min) statically but increased during motion (MAE = 5.03–5.21 breaths/min). SpO2 remained highly stable (MAE = 1.08–1.21%), well within standard clinical tolerance. SBP showed solid central accuracy (MAE = 6.48–7.51 mmHg) but wider LoA occasionally exceeded the ±5 mmHg threshold, functioning best as a continuous trend monitor. DBP variance was negligible (MAE = 4.65–5.46 mmHg). Conclusion The current SMART MAT is a viable, integrated multimodal platform. HR, RR, and DBP are comparable to clinical reference standards, while SBP requires careful interpretation. By accommodating a functional sitting posture, the contactless system reduces immobility-related complications and demonstrates high feasibility for continuous, real-world monitoring.

Read PDF

Similar papers

Open access Sep 2026

Contactless Vital Sign Monitoring in Emergency Settings: A Factorial Study of Camera Position and Motion Using rPPG

Reliable acquisition of vital signs is essential in prehospital emergency care; however, conventional contact-based sensors may delay assessment, cause patient discomfort, increase cross-contamination risk, and perform poorly during motion. To address these limitations, this study developed a body-worn smart camera sys...

Tae-Eun Kim, SangHyeok Kim, Jeong-Hyeon Moon et al. · 0 citations
Conference Open access 2026

Accuracy of Wearable Heart Rate Monitors under Static and High-Intensity Activity Conditions

The widespread adoption of wearable devices has created new opportunities for continuous monitoring of physical activity, cardiovascular health, and sleep patterns. However, it remains an open question to what extent the physiological and kinematic data provided by commercial smartwatches can be considered accurate and...

János Dávid Balogh, Attila Adamkó · 0 citations
Open access Feb 2026

Flexible pressure sensor pants for app-supported sleep posture monitoring: Feasibility, accuracy, and user experience study

Flexible pressure sensor pants demonstrated high accuracy, strong agreement with infrared monitoring, and high user satisfaction and practical convenience indicate their potential to meet essential requirements for sleep posture assessment.

Yong-En Miao, Jin-Chuan He, Ji Chen et al. · 0 citations
Open access Sep 2026

Validation study on cuffless ambulatory blood pressure monitoring method using bio-impedance, impedance cardiography and electrocardiography.

PURPOSE Continuous, non-invasive blood pressure (BP) monitoring is essential for understanding cardiovascular dynamics in real-world settings. This study evaluated the reliability and validity of a cuffless method for ambulatory BP monitoring using pulse wave travel times derived from bio-impedance, impedance cardiogra...

Myrte Schoenmakers, Martin J. Gevonden, B. Sauce et al. · 0 citations
Open access Sep 2026

An Integrated Web-Based Wearable System for Real-Time Multi Parameter Health Monitoring

Continuous health monitoring has become increasingly important for extending physiological assessment beyond conventional clinical environments, particularly where access to healthcare infrastructure and reliable internet connectivity is limited. This study presents a compact web-based wearable health monitoring sys...

Ifeloluwa Deborah Fadiran · 0 citations
Oct 2026

Comparative Assessment of PPG Signal Quality Across Fingers for Wearable Health Monitoring and Implications for Sensor Design Optimization

In clinical settings, every minute of delay in treating a cardiopulmonary emergency can reduce a patient's chance of survival by up to 10%. Photoplethysmography (PPG) is a low-cost, noninvasive method widely adopted in both clinical, and consumer settings to monitor cardiopulmonary signals. Therefore, clinical PPG puls...

Karlen Aleksanyan, Xue Xu, Zheng Liu et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.