Aug 2026· Inventions· Vol 11, pp. 81· 0 citations· 30 references
TL;DR
A probabilistic multi-phase workload model is developed to capture the temporal characteristics of training, fine-tuning, and inference processes, incorporating both high-frequency fluctuations and multi-day workload variations, demonstrating stable LDES operation without dynamic adjustment.
Abstract
The rapid growth of artificial intelligence (AI) data centers introduces highly variable and mission-critical load profiles that challenge conventional power supply strategies. This paper proposes an islanded microgrid gas turbine generator (GTG) and long-duration energy storage (LDES) hybrid architecture to provide both short-term load balancing and extended energy support under prolonged outage conditions. A probabilistic multi-phase workload model is developed to capture the temporal characteristics of training, fine-tuning, and inference processes, incorporating both high-frequency fluctuations and multi-day workload variations. Based on reliability requirements, an LDES sizing methodology is formulated to ensure long-duration autonomy for mission-critical operation in a 12 MW power-block AI data center system, with the storage capacity determined based on a 12-h autonomy criterion. The GTG operating point is then evaluated using four storage performance metrics: charge/discharge transition frequency, charging time ratio, state-of-charge (SoC) deviation, and cumulative energy movement. The results indicate that the optimal GTG operating point ranges from approximately 40–73.3% of the initially selected rating, closely tracking the time-varying average load and significantly reducing LDES utilization and storage stress. While GTG fixed-output operation may induce SoC drift under sustained workload variations, applying the identified optimal operating point maintains SoC within the desired range, demonstrating stable LDES operation without dynamic adjustment. The proposed framework provides quantitative design and operational guidelines for GTG–LDES hybrid systems in next-generation AI data centers.
This paper proposes a high-fidelity hyperscale data center load modeling framework that disaggregates facility demand into IT and non-IT components and represents load behavior at second- and minute-level resolutions. Building upon this foundation, a comprehensive multi-phase optimization framework is developed for the...
: The increasing penetration of renewable energy sources has made microgrids an important platform for local energy consumption, resilient power supply and flexible grid interaction. However, the variability of photovoltaic and wind generation, together with frequent changes in load demand and operating mode, places hi...
Guo-Ying Pan, Xue-Bin Li, Shi-Hao Wei et al.· Journal of Electrotechnology...· 0 citations
Extreme heat events can cause sustained load growth, reduced renewable power output, and increased source–load uncertainty, posing challenges to supply–demand balance in power systems with high renewable penetration. To address hourly power fluctuations and cross-day energy deficits under extreme heat conditions, this...
Ke-Qiang Tai, Xiu-Ting Rong, Yunlong Chu et al.· Energies· 0 citations
Background The increasing integration of renewable energy sources (RES) in power systems introduces operational challenges due to their intermittent and difficult-to-predict generation. Hybrid Energy Storage Systems (HESS) can mitigate these issues by providing flexibility and stability to microgrids. However, efficien...
Markel Azkue, A. Saez-de-Ibarra, Vincenzo Mascaro et al.· Open Research Europe· 0 citations
Active distribution networks (ADNs) require battery energy storage system (BESS) scheduling strategies that reduce operating costs while preserving electrical feasibility and battery lifetime. This paper proposes a parallel adapted JAYA-based methodology for the day-ahead coordinated active and reactive power dispatch...
L. Grisales-Noreña, O. Montoya, V. M. Garrido-Arévalo· Electricity· 1 citation
Long-duration energy storage (LDES) can mitigate prolonged renewable--load imbalances during Dunkelflaute events, but existing studies rely on zonal or linearized DC network models and inadequately analyze the operational feasibility of the grid across a wide range of full-year renewable, load, and contingency scenario...
Jeongdong Kim, Jonggeol Na, Sung-Ho Shin· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.