Skip to content
Open access

Ejection fraction on a budget: mapping the accuracy-compute trade space for video-based ejection fraction estimation

Sep 2026 · medRxiv · 0 citations
Medicine

TL;DR

Deep video networks estimate left ventricular ejection fraction from echocardiograms with expert-level accuracy, but the compute cost of running them is rarely reported, so this work sets a practical floor for how inexpensive this task can be.

Abstract

Deep video networks estimate left ventricular ejection fraction (EF) from echocardiograms with expert-level accuracy, but the compute cost of running them is rarely reported. This leaves anyone building a handheld or bedside tool without clear guidance on what to deploy. We measured the accuracy-versus-compute tradeoff for EF estimation on EchoNet-Dynamic by training 22 configurations that varied clip length (8 to 64 frames), frame sampling period (1 to 4), and backbone: R(2+1)D-18, R3D-18, MC3-18, X3D-S, X3D-M, and a 2D ResNet-18 with temporal pooling. All models used one fixed training recipe. Every configuration was evaluated for accuracy using mean absolute error, R-squared, and Bland-Altman agreement; clinical utility using sensitivity and specificity at the clinically relevant EF cutoffs of 40% and 50%, plus error stratified by EF band; and cost using floating-point operations, parameter count, GPU and CPU latency, and peak memory under a single frozen measurement protocol. We stress-tested the main findings with replicate training seeds. Sparse temporal sampling outperformed dense sampling at matched frame budgets. A sampling period of 4 outperformed a period of 1 at every tested frame count while also reducing per-video cost. In the seed-replicated 8-frame comparison, the advantage averaged one full point lower mean absolute error across all nine cross-seed pairings. A standard R3D-18 achieved the best accuracy in the study, with a mean absolute error of 3.99, while requiring 19% less CPU latency than the reference configuration. A 16-frame, period-4 R(2+1)D-18 cut reference cost in half with no statistically confirmed loss in accuracy. Removing temporal modeling entirely substantially reduced accuracy, with a mean absolute error of 5.65, setting a practical floor for how inexpensive this task can be. We release the code, cost-measurement protocol, and per-configuration results.

Read PDF

Similar papers

Preprint Sep 2026

The segmentation ceiling: why explicit left-ventricular masks do not improve learned ejection-fraction regression

Accurate estimation of left ventricular ejection fraction (EF) from echocardiography is central to cardiovascular care, and deep learning enables automated EF prediction from echocardiographic video. Because EF is clinically derived from left-ventricular (LV) volumes, a widely held intuition is that explicit LV segment...

F. F. Khouzani, P. La Plante, B. Shareef et al. · 0 citations
Open access Aug 2026

Learning from Scarce Labels: Multi-View Echocardiography for Ejection Fraction Prediction

This work creates the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography by leveraging a time-based correlation between clinical notes and echocardiographic videos and fine-tuning view classifiers and proxy labeling.

Zhiyuan Gao, Dominic Yurk, Yaser Abu-Mostafa · 0 citations

Machine Learning for Biomedical Imaging Learning from Scarce Labels: Multi-View Echocardiography for Ejection Fraction Prediction

This work creates the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography by leveraging a time-based correlation between clinical notes and echocardiographic videos and fine-tuning view classifiers and proxy labeling.

Zhiyuan Gao, Dominic Yurk, Yaser Abu-Mostafa et al. · 0 citations
Open access Sep 2026

Weakly supervised anatomical feature learning for cross-dataset ejection fraction estimation from echocardiography videos

The findings support controlled external validation under explicit image and target harmonization, while further prospective validation, calibration, and quality-control mechanisms are needed before clinical deployment.

Adrian Krenzer, Viktoria Wieser, Tobias Friedetzki · 0 citations

Multimodal Contrastive Learning with ECG and Echocardiography for Ejection Fraction Estimation

Multimodal pretraining improved frozen DINO models over the uni-modal baseline, but its benefits diminished after fine-tuning, suggesting that encoder initialization and down-stream adaptation were more influential than increasingly complex echocardiographic supervision.

Jad Haidamous, Laura Valeria Perez-Herrera, Miriam Guti'errez et al. · 0 citations
Open access 2026

Video-Based Temporal Attention Network for Automated Analysis of Left Ventricular Ejection Fraction

: The left ventricular ejection fraction (LVEF) is one of the most important quantitative indicators in cardiovascular medicine. It serves as a key measure for diagnosing, assessing risk, and guiding treatment decisions in conditions such as heart failure, cardiomyopathies, and coronary artery disease. However, obtaini...

Fazliddin Makhmudov, Jamshid Khamzaev, Jakhongir Karimberdiyev et al. · 0 citations