TL;DR
Fetal Heart Quantification is a quantitative method for assessing fetal ventricular morphology and function during a healthy pregnancy and more extensive and comprehensive studies are needed to standardize fetal HQ analyses for both healthy fetuses and those in complicated pregnancies.
Abstract
Background
Fetal Heart Quantification is a technology based on two-dimensional speckle-tracking imaging, which divides the fetal ventricle into 24 segments. It is used to quantitatively analyze and evaluate fetal heart morphology and function.
Materials And Methods
A prospective observational study was conducted among 52 healthy pregnant women between 18 and 22 weeks of gestation. The Fetal Heart Quantification technology was used to collect ultrasound images for studying fetal heart structure and function. The images were enhanced to define the boundary between the blood and the endocardium. Four-chamber images were recorded as 3-second clips in Digital Imaging and Communications in Medicine files and stored. Measurements of the right and left ventricles and the differences between the 24 segment measurements were recorded and evaluated. SPSS 26.0 was used to analyze variables. The Kolmogorov-Smirnov test was used to assess the normality of the data distribution. The Bootstrap and Monte Carlo simulation techniques were used to assess the robustness of the findings. Paired-samples T-test and Wilcoxon Signed-Rank test were used to compare dependent quantitative variables as appropriate. Partial correlation tests were conducted to determine the correlation between these variables. The variables were analyzed at a 95% confidence level, and a p-value of less than 0.05 was considered statistically significant.
Results
Significant differences between the right and left ventricles were observed for fractional area change (FAC), ventricle end-diastolic volume (EDV) area, ventricle end-systolic volume (ESV) area and length (p<0.05). There was no noticeable difference in the sphericity index values. Left ventricular 24-segment transverse fractional shortening (FS) was significantly greater than right ventricular FS at segments 1 and 23 (p<0.05). The ESV and cardiac output were positively correlated with estimated fetal weight, while cardiac output was positively correlated with ventricular EDV length (p<0.05). There were no significant relationships between the shape of ventricles, short axis shortening, or EDV and gestational age or Estimated Fetal Weight (p>0.05).
Conclusion
Fetal Heart Quantification is a quantitative method for assessing fetal ventricular morphology and function during a healthy pregnancy. More extensive and comprehensive studies, as well as meta-analyses involving different ethnic groups, are needed to standardize fetal HQ analyses for both healthy fetuses and those in complicated pregnancies, and to establish their diagnostic value.
The Tei index can be measured between 11 and 14 weeks of gestation using noninvasive ultrasound techniques and contributes to the limited literature on first-trimester fetal cardiac functional assessment.
S. Molina-Giraldo, Luis David Palau Pérez, Camilo Torres et al.· Journal of Clinical Ultrasou...· 0 citations
OBJECTIVE
Fetal growth restriction (FGR) is associated with increased perinatal morbidity and mortality. The fetal myocardial performance index (MPI) has been proposed as a marker of fetal cardiovascular adaptation for FGR; thus, this study aims to evaluate whether fetal MPI measured at 20-24 gestational weeks predicts...
Şeyma Kılıç, Nizamettin Bozbay, A. C. Duymuş et al.· Journal of Clinical Ultrasou...· 0 citations
Preliminary results show that the proposed AI model is capable of detecting deviations from normal fetal development, and is working to improve robustness, interpretability, and performance to contribute to its applicability in real-world clinical settings.
G. Steyde, C. Gorla, G. Magenes et al.· 0 citations
OBJECTIVES
Estimating fetal weight (EFW) is essential for decisions regarding mode of delivery, labour induction, and identification of at-risk fetuses. Deviations from expected weight may lead to labour complications and maternal or neonatal injury; therefore, abnormalities must be detected before delivery. There are...
A. Strojny, S. Feduniw, Arkadiusz Baran et al.· Ginekologia Polska· 0 citations
OBJECTIVE
To assess the association between fetal hyperechogenic bowel (FHB), detected through level II ultrasound, and early postnatal growth outcomes-birth weight, length, and head circumference-in a regional hospital in Taiwan.
MATERIALS AND METHODS
In this retrospective study, 158 neonates underwent prenatal leve...
Y. Huang, Kun-I Lin, An-Chyi Chen et al.· Taiwanese Journal of Obstetr...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.