Evaluating the Accuracy of Non-Invasive Pulsed-Wave Doppler Echocardiography in Measuring Fetal QT and PR Intervals: A Cross-sectional Study.

Aug 2026 · Current medical imaging · Vol 22 · 0 citations
Medicine

TL;DR

Pulsed-wave Doppler echocardiographic measurement of fetal QT and PR intervals is a practical, non-invasive, and easily accessible substitute for fMCG when it is not available for prenatal screening of cardiac repolarization and conduction abnormalities.

Abstract

INTRODUCTION Congenital Long QT Syndrome (LQTS) is a common cause of potentially life-threatening ventricular arrhythmias and sudden cardiac death in infants and children. Fetal Magnetocardiography (fMCG) is available in only a few specialized centers worldwide and offers accurate measurements of the QT and PR intervals. The aim of this study was to assess the diagnostic accuracy of PW Doppler echocardiographic measurement of fetal QT and PR intervals compared with the available normative data for fMCG.

Methods

576 pregnant women with singleton pregnancies (16-38 weeks' gestation) were studied in this cross-sectional study between 2022 and 2023 with detailed fetal echocardiograms. Standardized pulsed-wave Doppler techniques were used to measure the PR and QT intervals. Results were compared with published normative data for fMCG, adjusted for gestational age, and were also compared with contemporaneous fMCG in a subset of 42 fetuses.

Results

Mean QT interval (echo) was 270.0 ± 38.8 and mean PR interval was 119.3 ± 16.2. In the paired subset (n = 42), strong agreement was observed (PR ICC = 0.89 [95% CI: 0.81-0.94]; QT ICC = 0.82 [95% CI: 0.72-0.89]), with mean biases of +2.1 ms and +6.8 ms on Bland-Altman analysis, respectively. Sensitivity and specificity for the full cohort for prolonged intervals (> 95th percentile of GA-adjusted fMCG norms) were 85% and 78% (PPV 68%, NPV 90%). There were no clinically significant differences for PR interval or fetal heart rate, and there was no significant correlation between measured intervals and gestational age (p > 0.05).

Discussion

Pulsed-wave Doppler echocardiography is a reliable method for measuring fetal QT and PR intervals and is in good agreement with fMCG.

Conclusion

It is a practical, non-invasive, and easily accessible substitute for fMCG when it is not available for prenatal screening of cardiac repolarization and conduction abnormalities.

View source

Similar papers

Sep 2026

Reference Ranges for the Fetal Myocardial Performance Index Assessed by Conventional Doppler Between 11 + 0 and 14 + 0 Weeks of Gestation.

The Tei index can be measured between 11 and 14 weeks of gestation using noninvasive ultrasound techniques and contributes to the limited literature on first-trimester fetal cardiac functional assessment.

S. Molina-Giraldo, Luis David Palau Pérez, Camilo Torres et al. · 0 citations
Sep 2026

Agreement Between Echocardiography and Ultrasonic Cardiac Output Monitoring (USCOM) for Hemodynamic Assessment in Pediatric Patients: A Bland-Altman Analysis.

BACKGROUND Echocardiography is widely used for non-invasive measurements of stroke volume and cardiac output, while Ultrasonic Cardiac Output Monitor (USCOM) offers an alternative Doppler-based approach. Whether these two modalities can be used interchangeably in clinical practice remains unclear. This study aims to ev...

Saviga Sethasathien, Orana Arsasuwan, Theerapon Jariyasakoolroj et al. · 0 citations
Open access Sep 2026

Reference ranges, nomograms, and z-score equations for fetal aortic isthmus Doppler parameters during second-trimester anatomical assessment: a prospective cross-sectional study

Aims: This study aimed to establish gestational age-specific reference ranges, nomograms, and z-score equations for aortic isthmus (AoI) Doppler parameters between 18 and 24 weeks of gestation and to assess their relationships with fetal biometry and arterial Doppler measurements.Methods: In this prospective cross-sect...

B. Bayraktar · 0 citations
Open access Sep 2026

A study on comparison of non-stress test and Doppler velocimetry in assessment of fetal well-being in gestational diabetes mellitus

Background: Non-stress test (NST) and Doppler velocimetry are established tools for fetal surveillance. In gestational diabetes mellitus (GDM), a high risk pregnancy condition, antenatal monitoring is crucial to optimize perinatal outcomes. Aims and Objectives: This study aimed to compare the efficacy of NST and Dopple...

Paromita Roy, Madhumita De, Sangeeta Dubey et al. · 0 citations
Open access Oct 2026

Robust Approach to Measure Time-Resolved Septal Curvature in Pediatric Pulmonary Hypertension Patients Using Standard Short-Axis Ventricular Volume Contours: A Retrospective, Cross-Sectional Study.

BACKGROUND Right heart catheterization is the gold standard for diagnosis and monitoring of pediatric pulmonary hypertension (PH). Noninvasive cardiovascular magnetic resonance (CMR) and echocardiography can additionally provide volumetric and functional assessment of the right ventricle and possibly serve as a non-inv...

Takashi Fujiwara, Vivian Lu, B. Frank et al. · 0 citations
Sep 2026

Value of the Newly Designed Major and Minor Checklists in Diagnosis of Congenital Cardiovascular Disease and Associated Malformation: New Era of Fetal Cardiac MRI.

FCMRI is a useful complementary adjunct to fetal echocardiography, improving diagnostic confidence in complex cases and supporting prenatal counseling, delivery planning, and postnatal management.

H. G. Hassan, S. Ragheb, Ahmed M. Elyasaki et al. · 0 citations