Skip to content
Open access

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators

Aug 2026 · Physics in Medicine and Biology · Vol 71 · 0 citations · 30 references
Physics Medicine

TL;DR

The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Abstract

Objective. The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments. Approach. We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations. Main results. The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks. Significance. This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Read PDF

Similar papers

Open access Sep 2026

Study of a novel inverted collimator concept for prompt-gamma-based range verification in proton therapy using a hybrid simulation approach

Objective. Prompt-gamma imaging is a promising technique for in-situ range verification during proton therapy, with the potential to reduce range uncertainties. Current prompt-gamma cameras typically rely on mechanical collimators, among which the knife-edge slit (KES) and multi-parallel slit (MPS) collimators are the...

K. Urban, G. Borghi, M. Carminati et al. · 1 citation
Open access Aug 2026

Geometric Correction Method for Large-Area Pixel-Detectors for Improved Resolution in X-ray Imaging

Large-area hybrid pixel detectors are widely used in synchrotron facilities in small-angle X-ray scattering and crystallography beamlines but also for imaging techniques, due to their high dynamic range and single-photon sensitivity. However, their modular construction introduces gaps that limit the effective use of...

Tiago A. Kalile, Pedro H. Z. Guidolim, Florian Meneau · 0 citations
Preprint Oct 2026

A software tool for parametric collimator creation for linac-based preclinical irradiation studies

Designing custom Cerrobend collimators for linac-based preclinical electron irradiation is labor intensive and susceptible to design inconsistencies. We developed Collimator Creator (CC), an open source parametric workflow that converts aperture dimensions and jig offsets into printable STL models for a collimator mold...

J. B. Schulz, Di-Xin Chen, L. Ghomsi et al. · 0 citations
Open access Sep 2026

Development and optimization of a bakelite RPC-based muon tomography system

Cosmic-ray muon scattering tomography has emerged as a powerful non-invasive imaging technique for the detection of concealed high atomic number (high-Z) materials inside large and densely shielded objects, where conventional X-ray and gamma-ray imaging methods often face limitations. The technique exploits the multipl...

T. Das, Souvik Chattopadhay, S. Khan et al. · 0 citations
Preprint Sep 2026

Non-circular scan trajectories for reducing cone-beam artifacts in Gamma Knife CBCT images: a simulation study

Objective. Gamma Knife cone-beam computed tomography (CBCT) images are deteriorated by cone-beam artifacts whose magnitude increases along the superior direction. In this study, a novel scan trajectory compatible with the Gamma Knife CBCT system is optimized to reduce cone-beam artifacts, with the aim to replace the cu...

Alexandra Alain-Beaudoin, H. Nordström, Luc Beaulieu et al. · 1 citation · ⚡1
Open access Aug 2026

Introducing DIANA: dual-mode imaging analysis open-source simulation software

The use of the complementarity of the contrast between X-rays and neutrons for computed tomography is a well-established technique. X-rays are strongly attenuated by dense, high-atomic-number materials, while neutrons are particularly sensitive to light elements, such as hydrogen or lithium. Combining the information o...

O. Sans-Planell, S. Dayani, Nikolay Kardjilov et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.