Skip to content
Open access

Short-term Outcomes of Impaction Bone Grafting Technique with a Collared Fully Hydroxyapatite-Coated Stem in Revision Total Hip Arthroplasty: A Case Series

Aug 2026 · Journal of Orthopaedic Case Reports · Vol 16, pp. 363 - 369 · 0 citations · 1 references
Medicine

TL;DR

Short-term outcomes of revision THA with IBG using a collared fully HA-coated stem are favorable, supported by radiographic and CT evidence of bone ingrowth, is a useful and effective treatment option for femoral component revision.

Abstract

Abstract Introduction: Impaction bone grafting (IBG) with cemented stems in revision total hip arthroplasty (THA) is a well-established method, but reports using cementless stems are scarce. The purpose of this study is to report short-term outcomes of six revision THAs using the IBG technique with a collared fully hydroxyapatite (HA)-coated stem. Materials and Methods: From 2014 to 2021, six joints (median age 64.3 years; median follow-up 4.5 years) were revised for aseptic loosening (n = 5) or septic loosening (n = 1). All cases used the IBG technique with a collared fully HA-coated stem (CORAIL or UNIVERSIA). Full weight-bearing was allowed post-operative day 1. Outcomes included the Japanese Orthopedic Association Score, stem subsidence, and radiographic remodeling. Results: Median surgical time was 127 min; blood loss was 855 mL. No complications (infection, polyethylene wear, loosening, or dislocation) occurred. The JOA score improved from 63 (preoperatively) to 95 (final follow-up). Median stem subsidence was 1.4 mm (1–3 mm), with no case >5 mm. Radiographs showed no radiolucent lines and remodeling in all cases. Computed tomography (CT) images of one case confirmed bone ingrowth between the stem and the compressed allograft. Conclusion: Short-term outcomes of revision THA with IBG using a collared fully HA-coated stem are favorable. This technique, supported by radiographic and CT evidence of bone ingrowth, is a useful and effective treatment option for femoral component revision.

Read PDF

Similar papers

Sep 2026

LONG-TERM OUTCOMES OF METAPHYSEAL CONES IN REVISION TOTAL KNEE ARTHROPLASTY: A RETROSPECTIVE STUDY OF 256 CASES

Bone loss remains one of the challenges in revision total knee arthroplasty (rTKA). Trabecular Metal (TM) metaphyseal cones have been increasingly used to achieve stable fixation. While short- and mid-term results are promising, long-term outcomes remain poorly documented. The objective of this study was to evaluat...

J. Argenson, François-Xavier Neumann, Mathieu Ollivier et al. · 0 citations
Review Sep 2026

Is the use of primary cementless stem in revision total hip arthroplasty a reliable option? A systematic review.

Cementless primary femoral stems are a reliable option for rTHA in patients with preserved metaphyseal bone, demonstrating low aseptic loosening rates and favorable functional outcomes at mid- to long-term follow-up.

N. Corradi, A. Trimarchi, A. L. Soldati et al. · 0 citations
Review Open access Aug 2026

Early Periprosthetic Femoral Fractures and Stem Subsidence After Direct Anterior Total Hip Arthroplasty Using a Collared, Fully Hydroxyapatite-Coated Stem

Stratification by trauma mechanism may help identify fractures requiring surgery, whereas non-traumatic fractures and most subsidence cases were successfully managed non-operatively.

Hiroshige Hamada, Y. Miura, T. Ninomiya et al. · 0 citations
Open access Sep 2026

Cemented dual mobility component in newly implanted porous tantalum shells for severe acetabular defects: medium-term outcomes from a high-volume single-surgeon series

DMCs cemented into PT shells could be considered an effective management of severe acetabular bone defects without pelvic discontinuity providing excellent clinical and radiographic results in the mid-term.

M. Loppini, V. Di Matteo, Alberto Bulgarelli et al. · 0 citations
Open access Sep 2026

Patterns and Risk Factors of Aseptic Loosening in a Hydroxyapatite-Coated Cementless Quadrangular Taper Femoral Stem: A Single-Center Cohort Study

Background There have been several reports of metaphyseal debonding of hydroxyapatite (HA)-coated cementless quadrangular taper femoral stems leading to revisions for aseptic loosening. This study aimed to assess the characteristics and risk factors of this type of revision. Methods A single-center cohort of total hip...

R. Bansal, C. Righolt, T. Gascoyne et al. · 0 citations
Review Open access Aug 2026

Satisfactory Survivorship and Clinical Outcomes After Acetabular Revision With the Three-Dimensional–Printed Porous Metal Monoblock Dual-Mobility Cup: A Retrospective Case Series With Mean 3 Years Follow-Up

Background Acetabular revision total hip arthroplasty is associated with high rates of instability and aseptic loosening. Dual-mobility cups (DMCs) reduce dislocation risk and three-dimensional (3D)-printed porous metal surfaces enhance biologic fixation. The combination of these 2 technologies in a monoblock cementles...

Edoardo Guazzoni, Andrea Maria Di Prima, M. Di Maio et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.