Toward CT-Equivalent Image Quality in Low-Dose Radiotherapy Planning: Conditional Diffusion-Based CBCT-to-CT Synthesis and the Impact of CBCT Input Representation
This study develops a supervised deep learning based CBCT to CT synthesis framework using a conditional denoising diffusion probabilistic model (DDPM), where the generation of a CT-based planning for accurate positioning and dose calculation is obtained using generative models with low dose CBCT imaging.
Abstract
During standard radiotherapy planning, repeated CT acquisitions are often required for patient registration, verification, and adaptive planning, resulting in increased cumulative X-ray dose. To mitigate this, low-dose cone-beam CT (CBCT) is routinely acquired during treatment delivery. However, CBCT image quality remains insufficient for accurate dose calculation and adaptive radiotherapy planning due to increased scatter, noise, beam hardening, and reconstruction related artifacts. This study develops a supervised deep learning based CBCT to CT synthesis framework using a conditional denoising diffusion probabilistic model (DDPM), where the generation of a CT-based planning for accurate positioning and dose calculation is obtained using generative models with low dose CBCT imaging. Beyond demonstrating CBCT to CT synthesis, the primary objective is to investigate how the representation of CBCT input data, either standard clinical DICOM CBCT images or filtered back-projection (FDK) reconstructions from raw projection data, affects the performance of diffusion based CT synthesis. The overarching aim is to assess whether physics aware CBCT representations better support CT-equivalent image quality while maintaining reduced imaging dose in radiotherapy workflows.
Improved quantitative accuracy in CBCT through robust scatter suppression enhances deep learning-based segmentation, particularly for large organs, supporting its role in improving adaptive radiotherapy workflows.
R. Dotel, Farhang Bayat, Jun-Xiao Hu et al.· Physics and Imaging in Radia...· 0 citations
Objective. Range uncertainties in proton therapy largely arise from the semi-empirical conversion of x-ray computed tomography (CT) Hounsfield Units to stopping power relative to water (RSP), requiring generous safety margins or robust optimization. Pencil beam-wise integrated depth-dose profiles (IDDs), obtained via p...
Ines Butz, K. Parodi, C. Gianoli· Physics in Medicine and Biol...· 0 citations
Daily CBCT image-guided couch corrections maintain dosimetric accuracy during hypofractionated prostate radiotherapy and support safe implementation of tight PTV margins in resource-constrained public-sector healthcare settings.
Leanore Legoale-Sebopa, Sheynaz Bassa, H. V. Maselesele· South African Journal of Onc...· 0 citations
Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy, but scatter, beam hardening, noise, truncation, and other artifacts limit image quality and CT number accuracy. Paired CBCT and CT data are difficult to obtain clinically because of motion, anatomical changes, and acquisition mismatch. We...