Skip to content
Open access

Interval-Level Validation of a Wearable Dry-Electrode ECG Biosensor Platform: A Proof-of-Concept Study

Sep 2026 · Biosensors · Vol 16 · 0 citations · 38 references
Medicine

TL;DR

Preliminary evidence of interval-level agreement for the X-trodes wearable dry-electrode ECG biosensor platform under controlled, short-duration daytime conditions is provided.

Abstract

Wearable dry-electrode electrocardiographic (ECG) systems may enable longer and more comfortable rhythm monitoring, but their interval-level measurement fidelity requires validation against reference acquisition systems. In this single-center proof-of-concept study, 20 participants (10 healthy volunteers and 10 cardiology patients) underwent simultaneous ECG recordings with a U.S. Food and Drug Administration (FDA)-cleared wearable dry-electrode platform (X-trodes System M) and a wired reference system (MP150 with ECG100C module, Biopac Systems). Three-minute paired segments were recorded and underwent temporal synchronization, bandpass filtering, baseline correction, automated discrete-wavelet peak detection in NeuroKit2 (version 0.2.10), and standardized manual adjudication. After predefined exclusions for temporal alignment and P-wave detection quality, agreement was assessed in nine cardiac and ten healthy participants for RR intervals and in seven cardiac and eight healthy participants for P-to-R peak intervals. RR interval agreement was excellent in the healthy and cardiac cohorts, with a mean bias of 0.4 ± 3.1 ms and 0.1 ± 4.6 ms and mean absolute error (MAE) of 0.97 ms and 1.28 ms, respectively. Intraclass correlation coefficient (ICC) was over 0.99 for both cohorts. P-to-R peak interval agreement was strong, with an MAE of 1.76 ms and 7.14 ms and ICC of 0.96 and 0.98, respectively. These findings provide preliminary evidence of interval-level agreement for the X-trodes wearable dry-electrode ECG biosensor platform under controlled, short-duration daytime conditions. Because the matched interval pairs were clustered within a small number of participants, the findings should be regarded as proof-of-concept evidence supporting larger ambulatory validation studies rather than as definitive clinical validation.

Read PDF

Similar papers

Review Open access Sep 2026

Evaluation of a Consumer Wearable Smartwatch for Cardiac Interval Measurement in Healthy Adults: Cross-Sectional Method Comparison Study

Abstract Background Commercially available wearable devices, capable of measuring cardiac rhythm, are gaining popularity for convenient heart health monitoring. Accurate measurement of key intervals, specifically RR intervals for rhythm and QT and corrected QT (QTc) intervals for arrhythmia risk, is crucial for assessi...

Nicholas Noggle, David Wing, J. Godino et al. · 0 citations
Open access Aug 2026

Development and Clinical Evaluation of a Wearable 12-Lead Electrocardiographic Platform with Automated ECG Analysis for Telemedicine Applications

Wearable electrocardiographic technologies have become increasingly important for continuous cardiac monitoring; however, most existing portable systems are limited by the number of recorded leads or provide only basic signal acquisition without advanced automated analysis. This study presents a third-generation wearab...

Z. Alimbayeva, C. Alimbayev, K. Ozhikenov et al. · 0 citations
Open access Sep 2026

Development and validation of an integrated wearable system for continuous cardiorespiratory monitoring using photoplethysmography and optical respiratory detection.

Cardiovascular diseases remain the leading cause of mortality worldwide, with ischaemic heart disease the leading contributor and acute myocardial infarction accounting for the majority of ischaemic heart disease deaths. This study presents the development and technical validation of a low-cost, integrated wearable sys...

Jesús David Ramírez, N. Toro, Juan Manuel Devaldenebro Campo et al. · 0 citations
Open access Oct 2026

Inter-Lead RRI Agreement Between Lead I and Lead II Across Diagnostic ECG Categories: Pilot Evidence for Wearable HRV Monitoring

Background: Wearable electrocardiogram (ECG) devices capable of recording a single-lead signal—typically Lead I—have proliferated rapidly, enabling long-term ambulatory cardiac monitoring outside clinical settings. However, the extent to which Lead I-derived heart rate variability (HRV) metrics are concordant with thos...

Naoya Morikawa, Emi Yuda · 0 citations
Review Open access Aug 2026

A Review of Wearable ECG System Design and Key Technologies

Wearable electrocardiogram (ECG) monitoring has attracted increasing attention as cardiovascular diseases remain a major global health concern and long-term physiological monitoring is shifting from clinical settings to daily life. Despite recent advances in wearable healthcare technologies, reliable and low-power ECG...

Yu-Kai Sun · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.