Workflows for the Photopic Negative Response and the Baby Vision Test.

Aug 2026 · Journal of Visualized Experiments · Vol 234 · 0 citations
Medicine

TL;DR

A standardized 6E workflow is proposed, encompassing Environment, Equipment, Examinee, Electrode, Examination, and Exit, designed to improve the clinical feasibility and implementation of PhNR and Baby Vision testing, supporting their broader application in the diagnosis and management of glaucoma and pediatric visual disorders.

Abstract

Visual electrophysiological tests are noninvasive, objective tools widely used in clinical ophthalmology. However, two promising modalities, the photopic negative response (PhNR), which assesses inner retinal and retinal ganglion cell function, and the dynamic target-based Baby Vision Test, remain underutilized in clinical practice despite their ability to provide valuable objective functional data. Limited adoption is primarily due to procedural variability, numerous confounding factors, and challenges in result interpretation. To address these barriers, clear and standardized operational protocols are essential for maximizing their diagnostic potential. Here, a standardized 6E workflow is proposed, encompassing Environment, Equipment, Examinee, Electrode, Examination, and Exit, designed to improve the clinical feasibility and implementation of these tests. In a retrospective analysis, implementation of the 6E protocol significantly increased the proportion of infants who successfully completed testing. Specifically, the PhNR test success rate increased from 61.54% to 86.45% (p < 0.05), while the average duration of the Baby Vision Test decreased from 17.44 ± 9.89 min to 13.28 ± 9.24 min (p < 0.05). These findings demonstrate that the 6E workflow enhances the clinical utility and efficiency of PhNR and Baby Vision testing, supporting their broader application in the diagnosis and management of glaucoma and pediatric visual disorders.

View source

Similar papers

Review Open access Aug 2026

Smartphone-Based Fundus Imaging in Global Eye Care: Closing the Gap.

Small-scale implementation and cost-effectiveness studies are needed to determine whether improved access to ophthalmic imaging can translate into sustainable and equitable eye-care services, and minimum reporting standards are suggested to increase comparability across studies.

R. Lechtenboehmer, C. Cleland, F. Malerbi et al. · 0 citations
Review Open access Sep 2026

Wearable technologies in ophthalmic care and visual science.

A scoping review of English-language publications from 2018 to 2025 concerning wearable device classes, ophthalmic applications, the analytical roles of artificial intelligence, evidence maturity, and barriers to translation found most systems remain at the technical validation or early clinical feasibility stage.

Dan-Ni Qiao, Kai-Kai Zhao, Jing-Jing Jiang et al. · 0 citations
Review Open access Sep 2026

Artificial intelligence in ophthalmology: From diagnostic accuracy to clinical application

The limits of using high-performing artificial intelligence systems in ocular image processing, which seldom lead to enhanced patient outcomes, are assessed and the scientific, clinical, and practical techniques required to close this gap are delineated.

Marco Zeppieri, Matteo Capobianco, Federico Visalli et al. · 0 citations
Sep 2026

Digital Color Vision Testing in Optic Neuropathy: Are Smartphone Apps Ready for Clinical Use?

BACKGROUND Color vision impairment is a common feature of optic neuropathy, typically assessed with the printed Ishihara booklet. Smartphone-based alternatives are increasingly used, but their diagnostic performance in optic neuropathy is incompletely established. METHODS In this prospective, single-center diagnostic...

Amit Lejtman, A. Rosenblatt, Nemer Sayed Ahmad et al. · 0 citations
Review Sep 2026

Guidance (challenges and priorities) in the assessment of children with low vision: ERN-EYE clinical consensus statement.

Across Europe, children living with low vision often face inconsistent approaches to the assessment of their visual function, leading to delays in diagnosis and unequal access to care. To address this gap, a multidisciplinary group of experts from eight European countries developed a clinical consensus statement (CCS),...

A. Suppiej, C. Ceccato, Riccardo Maggi et al. · 0 citations
Review Aug 2026

Repeatability of near point of fixation disparity test.

CLINICAL RELEVANCE Vergence assessment is a fundamental component of binocular vision evaluation, enabling clinicians to detect and monitor conditions such as convergence insufficiency. Accurate and repeatable clinical tests are essential for reliable diagnosis and for tracking patient progress over time. BACKGROUND...

Mosaad Alhassan, Rathath Alrehaili, Lena Alnifai et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.