Control-Barrier-Function Shielded Conservative Distributional Reinforcement Learning for Anti-Misoperation AGC of Thermal Power Units

2026 · Energy Engineering · 0 citations · 56 references

Abstract

: High shares of variable renewable generation increasingly require thermal units to provide deeper, faster, and more frequent automatic generation control (AGC) while operating close to low-load, steam-pressure, ramp-rate, and actuator limits. Under these conditions, an area-level regulation request that is valid for grid balancing can become unsafe at the plant interface because of nonlinear boiler–turbine dynamics, delayed measurements, sensor bias, and compound disturbances. This study therefore formulates AGC from the plant side: an area-level dispatcher allocates regulation among thermal generation, hydro generation, battery storage, and flexible load, while the proposed controller modifies only the command assigned to a 600 MW reheat thermal unit before it enters the plant distributed control system. A control-barrier-function (CBF) shielded conservative distributional reinforcement learning method is developed to prevent excessive ramping, steam-pressure excursions, valve over-actuation, low-load instability, and errors caused by delayed or biased measurements. Every transition used for training, validation, and testing is generated numerically by the declared behavior policy and benchmark generator; no measured AGC record or plant-historian data enter the reported results. Asynchronous signals are causally aligned on a 4 s decision grid, and a dedicated distributional safety-cost critic estimates the 0.95 conditional value-at-risk (CVaR) of discounted constraint cost. The nonlinear simulator is additionally cross-checked against the published plant-derived Bell–Åström model at seven operating points. Normalized power-transient NRMSE is 0.021–0.079 with correlation 𝑟 ≥ 0.995 , while pressure-transient NRMSE is 0.084–0.254 with 𝑟 = 0.733 –0.970. Ten independent training seeds and 3500 held-out numerical episodes show that the controller reduces cumulative absolute ACE from 218 to 165 MW min and improves the frequency nadir from −0.073 to −0.041 Hz relative to PI AGC. No hard violation occurs in 525,000 feasible test decisions, giving a one-sided 95% binomial upper bound of 0.00057% on the per-decision violation probability. The safety statement remains conditional on the declared plant model, uncertainty set, robust control-invariant subset, and bounded prediction errors. End-to-end CPU execution requires 6.8 ms on average and 9.6 ms at the 95th percentile.

Read PDF

Similar papers

Conference Open access Sep 2026

Adaptive AI-Driven Control System for Real-Time Regulation of Kaplan Turbines in Small and Medium Hydropower Plants

This paper proposes an adaptive, AI-driven control architecture for real-time regulation of Kaplan turbines in small and medium hydropower plants, targeting simultaneous power tracking, reservoir level stabilization, and cavitation-aware operation. A cascade control structure is adopted, where an outer level loop enfor...

P. Stanchev, Nikolay Hinov, A. Salimov · 0 citations
Open access Sep 2026

Fast Frequency Control of VSC-Supported Low-Inertia Power Systems Using Enhanced Prioritized Reinforcement Learning

An application-oriented enhanced prioritized reinforcement learning strategy for fast frequency control of VSC-supported low-inertia power systems and demonstrates favorable transient regulation, empirical robustness and generalization within the investigated operating range, and low online computational burden.

Lan-Lan Wu, F. Jia, Xiao-Jie Jiang et al. · 0 citations
Open access 2026

Physics-Consistent Safe Reinforcement Learning With Risk-Adaptive Stochastic MPC for Cyber-Resilient AC Microgrids

Learning-based microgrid energy management has matured rapidly, yet existing safe-reinforcement-learning (RL) and stochastic-MPC hybrids typically treat the AC network as a power-balance constraint and the battery as a scalar state-of-charge integrator. Both abstractions discard the physics that determines whether a co...

Ali Sayghe, Ahmad Bakht Sultan, M. Mousa · 0 citations
Open access Sep 2026

Energy-Based Flatness Control for Islanded Hybrid Microgrids: Robustness Evaluation Under Uncertain Parameters and Measurement Noise

In battery energy storage systems (BESSs) in microgrids, traditional proportional–integral (PI) controllers remain a popular choice for management. The PI-based system often fails during sharp transients and under sudden shifts in solar irradiance or load demands. PI-based systems typically exhibit sluggish recovery ti...

Haider H. Ali, Basil H. Jasim, A. Alqurashi et al. · 0 citations
Conference Aug 2026

A Hierarchical Nonlinear Predictive Controller for Ramp-rate Mitigation in Hybrid Energy Systems with Solar Photovoltaics

Stringent ramp-rate constraints due to high solar photovoltaic (PV) penetration in power systems challenge conventional smoothing techniques, where capacity saturation and device degradation become critical bottlenecks. In this context, PV smoothing is posed as a constrained dispatch objective to shape the grid-facing...

Madiha Akbar, Mads R. Almassalkhi, Hamid R. Ossareh · 0 citations
Open access Aug 2026

Artificial Intelligence-Based Adaptive Control of a Liquid Resistance Starter for a 5 MW Slip-Ring Induction Motor in Oil and Gas Installations

High-power slip-ring induction motors remain important in oil and gas installations where high breakaway torque, restricted network capacity and severe operating conditions complicate starting. Conventional liquid resistance starters (LRSs) generally follow a predetermined electrode-travel schedule and therefore cannot...

Muralidharan Dhandapani, Soumyakant Satapathy · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.