Solid-State Transformers (SSTs) are increasingly proposed as the interface between distribution grids and data centers due to flexible power flows and fast dynamic response. However, when a short-circuit fault occurs in a load branch, the SST with a voltage-source-type DC-DC stage is forced to shut down due to fault currents. Therefore, current-limiting strategies are strongly needed to prevent catastrophic equipment damage and cascading blackouts by instantly restricting massive current spikes and offering sufficient currents for protection devices to act at the faulted branch. This paper proposes a coordinated DC load fault-tolerant current-limiting and recovery strategy embedded directly in the control of the SST DC-DC stage, avoiding additional hardware cost. Specifically, the fault mechanism of an example LLC resonant converter is studied. Accordingly, a fault detection framework is implemented, a closed-loop current controller is proposed to limit the DC current to a designated value within microseconds by surging the switching frequency and adjusting the duty cycle, and a ramped recovery stage will then restore the DC bus after the fault isolation without inrush currents. Experiments on an LLC converter prototype have verified the feasibility of the proposed current-limiting strategy, enabling faster and lower-cost fault response suitable for resilient data center power architectures.
The rapid expansion of voltage source converter-based high voltage DC grids has made DC fault protection a critical research priority, due to low network impedance and the absence of natural current zero crossings. DC fault current limiters have emerged as an effective means of suppressing the rapid rise of fault curre...
Mohammad Soltani Mohammadi, Saeed Norouztamar, Hossein Iman-Eini et al.· IEEE Open Journal of Power E...· 0 citations
Low-voltage DC–DC converters (LDCs) require high availability to prevent critical vehicle accidents caused by abrupt voltage drops resulting from switch faults. Therefore, rapid fault detection and technologies that ensure safe operation during fault conditions are essential. This paper proposes a fault-leg identificat...
Jin-Su Jang, Tae-Hyeon Lim, Seung-Hyeon Cho et al.· IEEE Access· 0 citations
In recent years, high penetrations of inverter-based resources are posing significant challenges to the medium-voltage networks, in which protection schemes based on high fault currents and unidirectional power flow may not perform as expected. This paper proposes a dynamic fault-detection and relay-coordination scheme...
Muhammad Abdul Rauf, Munira Batool, I. Madni· Energies· 0 citations
Driven by the “dual carbon” goals, the large-scale application of renewable power generation, DC distribution networks, and energy storage systems has increasingly highlighted the short-circuit protection challenges in low-voltage DC (LVDC) systems. LVDC faults are characterized by rapidly rising fault currents and the...
Solid-state circuit breakers (SSCBs) provide fast, arcless fault clearance, resulting in a longer service life compared to mechanical circuit breakers (MCBs) in DC grids. Black-start operations refers to the process of restarting a grid without an external power source, usually using the system’s internal energy storag...
Hans Vincent Lianto, A. Ghias, Volkert Pickert et al.· Energies· 0 citations