Skip to content
Open access

Machine Learning Classification of Migraine Using fNIRS During a Postural Task

Aug 2026 · Brain Science · Vol 16, pp. 927 · 0 citations · 58 references
Medicine

TL;DR

A wide-scale pipeline achieved a robust, validated separation of migraine from screened controls, carried by a distributed venous-weighted deoxyhemoglobin signature; specificity against other headache disorders remains to be established.

Abstract

Background: Migraine diagnosis and severity staging rest on clinical interviews according to the ICHD-3 criteria, with no validated objective biomarker. Functional near-infrared spectroscopy (fNIRS) is a portable and non-invasive method, but existing fNIRS migraine classification studies remain relatively small and rely on cognitive tasks. We assessed whether prefrontal hemodynamic responses with a head-down-to-knees maneuver separate migraine patients from controls, and high- from low-severity migraine. Methods: Prefrontal fNIRS, including short separation channels, was recorded during the maneuver in 50 interictal migraine patients and 52 controls screened for the absence of migraine, serious chronic conditions and hypertension. Nine hemodynamic parameters per chromophore (HbO, Hb and HbT) across thirty channels entered a hypothesis-neutral pipeline of 270 candidate pipelines (3 chromophores × 3 feature selection strategies × 30 classifiers) with no predefined region of interest. Results: Deoxyhemoglobin features selected by embedded L1 regularization with shrinkage-regularized linear discriminant analysis separated the groups with 92% balanced accuracy on the internal hold-out (92% sensitivity, 92% specificity, ROC-AUC 0.99; permutation p = 3 × 10−4), against 87% in development-set cross-validation and 88% under nested selection cross-validation, with a selection bias of +0.03. High- vs. low-severity classification (19 high, 31 low) did not exceed chance under nested validation (45%; permutation p = 0.45). Conclusions: A wide-scale pipeline achieved a robust, validated separation of migraine from screened controls, carried by a distributed venous-weighted deoxyhemoglobin signature; specificity against other headache disorders remains to be established. Attack frequency severity was not separable above chance, indicating that scalar hemodynamic descriptors are sufficient for a categorical but not a graded contrast.

Read PDF

Similar papers

Open access Sep 2026

Machine learning classification of fNIRS signals in patients with major depressive disorder and healthy controls

Objective To determine whether combining resting-state and the verbal fluency task (VFT) prefrontal fNIRS features with machine learning can distinguish patients with MDD from healthy controls (HCs), and to clarify the relative contributions of functional connectivity (FC) versus amplitude features to classification. M...

Zhuoyan Shan, Xia Liu, Xin-Yu Lin et al. · 0 citations
Open access Aug 2026

Machine and Deep Learning Approaches for Migraine Diagnosis and Classification: Advances and Challenges

Future studies should focus on developing explainable and multimodal frameworks, supported by cross-institutional collaborations and prospective validation, to ensure both methodological robustness and clinical credibility.

Rukiye Ölçüoğlu, Muhlis Yiğitcan Dağ · 0 citations
Open access Oct 2026

Hyperlet Transform-Based Cognitive Load Assessment Using Single-Channel fNIRS Signals

Abstract Cognitive load assessment using functional nearinfrared spectroscopy (fNIRS) has gained increasing attention due to its non-invasive and high spatial resolution nature. However, reliable classification remains challenging due to non-stationary and nonlinear nature of haemodynamic signals. Conventional time-fre...

B. Parthiban, Podakanti Satyajith Chary, N. Ganapathy · 0 citations
Sep 2026

Multidomain Electroencephalography Biomarker Fusion for Machine Learning-Based Dementia Classification.

Electroencephalography (EEG) has been investigated as a noninvasive approach for characterizing brain activity in neurodegenerative conditions. This study evaluated whether multidomain EEG biomarkers could distinguish Alzheimer's disease (AD), frontotemporal dementia (FTD), and healthy controls (HC). The publicly avail...

Jobin Thomas, Sweet Subhashree, S. Mohanty et al. · 0 citations
Sep 2026

Multimodal machine learning model integrating electroencephalography, heart rate variability and clinical measures for distinguishing major psychiatric disorders.

BACKGROUND This study aimed to develop and evaluate multimodal machine learning (ML) approaches for differentiating bipolar disorder (BD), major depressive disorder (MDD), and schizophrenia (SZ), conditions that are clinically difficult to distinguish because of overlapping symptom presentations despite their distinct...

Byeongjae Kang, Ji-Yoon Lee, J. Chang et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.