With the increasing integration of large-scale renewable energy sources (RESs), modern power grids are evolving into low-inertia and weak-damping networks, creating challenges for transient power-angle stability. Conventional grid-following (GFL) control strategies present a lagging synchronization response under weak grid conditions due to their reliance on phase-locked loops (PLLs). Although grid-forming (GFM) control via virtual synchronous generators (VSGs) provides standalone voltage source properties, conventional fixed-parameter VSGs exhibit an inherent design trade-off between first-swing angular suppression and post-fault oscillation damping during severe short-circuit disturbances. To resolve these vulnerabilities, this paper proposes an adaptive VSG control strategy designed to improve the transient power-angle response of the investigated system. By establishing a parametric judgment framework based on real-time frequency deviations and acceleration rates, the virtual inertia Jt and damping coefficient Dt are adaptively adjusted within predefined limits. Furthermore, a current-limiting mechanism is incorporated into the parameter adaptation loops to prevent converter overcurrent tripping. To evaluate the proposed method, an aggregated grid-connected benchmark system comprising a 5 MVA PMSG-based wind farm, a conventional synchronous generator, and an external grid is implemented in MATLAB/Simulink. The simulation results under continuous ambient operational fluctuations and severe three-phase short-circuit faults demonstrate that the proposed strategy reduces the first-swing power-angle peak by approximately 31% compared with the conventional fixed-parameter VSG, and the response settles within approximately 0.4 s in the investigated fault case. These results indicate the simulation-based feasibility of the proposed bounded adaptive strategy. Further real-time, hardware-in-the-loop, and experimental validation is required before practical implementation.
This paper proposes an adaptive virtual synchronous generator (AVSG) control strategy for three-phase grid-forming (GFM) inverters to enhance the stability and dynamic performance under power disturbances. Unlike conventional methods that use frequency deviation to adjust the VSG inertia and damping coefficients, the p...
Abdelhafid Cherifi, Abdelhalim Kessal, A. Chouder et al.· Journal of Sensor and Actuat...· 0 citations
With increasing renewable penetration, virtual synchronous generators (VSGs) have become an important solution for stabilizing converter-interfaced renewable generation because of their inertia support and grid-forming capability. However, under weak-grid voltage sag conditions, the transient synchronizing stability of...
Gang Li, Hao-Zheng Xu, Jia-Hui Wang et al.· Engineering Research Express· 0 citations
Grid-following converters are prone to transient synchronization instability during grid faults, which may lead to the disconnection of renewable energy devices and threaten the security and stability of power systems. To address this issue, this paper first establishes a second-order nonlinear reduced-order model cent...
To enhance the frequency support capability of wind–storage systems under high wind power penetration and alleviate the coupling among virtual inertia, damping, and active-power–frequency branch parameters in conventional grid-forming/virtual synchronous generator control, this paper proposes a damping–inertia adaptive...
Yi-Feng Zhu, Jie Chen, Jian-Bing Lv et al.· Electrical Engineering· 0 citations
Grid-forming virtual synchronous generators may experience low-frequency instability when controller settings change or network strength change. To examine this issue, a small-signal representation of a single grid-connected VSG is developed. The model incorporates power regulation dynamics, impedance emulation, cascad...
Shi-Yu Zhou, Shu-Huan Li, Yu-Qing Gu et al.· 2026 6th Power System and Gr...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.