A digital-twin framework is presented that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours.
Abstract
Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.
An uncertainty-guided digital twin framework that forecasts treatment-day anatomy before treatment and evaluates whether it generates online adaptive proton therapy (APT) plans of clinical quality generates online APT plans comparable in quality to physician-approved offline replans.
Yi-Zhou Wu, R. Sanford, Hui-Qiao Xie et al.· arXiv.org· 0 citations
Clinical-context-Aware and Patient-adaptive Deformable Image Registration can improve contour usability and dose mapping for adaptive radiotherapy and show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.
Cai-Wen Jiang, Song-Lin Zhao, Yu-Zhen Ding et al.· 1 citation
This study aimed to evaluate the feasibility of estimating patient positional errors during head-and-neck fixed-field intensity-modulated radiation therapy (IMRT) using a machine-learning (ML) regression models based on radiomics features of patient-transmitted fluence maps acquired by an electronic portal imaging devi...
Takayuki Nishikata, S. Utsunomiya, Madoka Sakai et al.· Medical Engineering and Phys...· 0 citations
An integrated software framework for patient-specific virtual GammaTile planning can connect anticipated tile placement with calculated dose and adjacent neuroanatomy and demonstrate feasibility and establish a framework for prospective validation and future comparison of candidate implant arrangements.
S. Bahadir, G. Thomas, F. Ablyazova et al.· medRxiv· 0 citations
Abstract Background Online adaptive radiotherapy (oART) accounts for anatomical changes by adjusting treatment plans on a daily basis. However, comprehensive plan‐specific quality assurance (QA) is challenging, as pre‐treatment measurements cannot be performed with the patient on the treatment couch. Therefore, an end‐...
J. Niedling, R. Schindhelm, Luis Cervantes et al.· Journal of Applied Clinical...· 0 citations
OBJECTIVE
This study evaluates the performance and sensitivity of an optimization-based registration framework for mosaicking partially overlapping 3-D ultrasound volumes to expand the clinical field of view. We specifically characterize the algorithm's ability to recover from varying degrees of initial tracking uncert...
M. Antico, S. Mason, E. Harris et al.· Ultrasound in Medicine and B...· 0 citations