Skip to content
Open access

Plaque-Adapted Virtual Monoenergetic Image Selection for Carotid Plaque Visualization Using Photon-Counting CT

Aug 2026 · Diagnostics · Vol 16, pp. 2774 · 0 citations · 36 references
Medicine

TL;DR

The findings support implementing standardized protocols with automatic dual-range reconstructions to enable efficient, individualized carotid plaque assessment in clinical practice and support implementing standardized protocols with automatic dual-range reconstructions for keV selection based on plaque composition.

Abstract

Objectives: The objective of this study was to evaluate the impact of virtual monoenergetic image (VMI) reconstructions derived from photon-counting computed tomography (PCCT) on the assessment of carotid arteries, with a focus on optimizing keV selection based on plaque composition. Methods: This retrospective study included 111 patients (mean age 80 ± 7.5 years; 64 men; 47 women) with carotid sclerosis who underwent PCCT between April 2022 and February 2023. One lesion was analyzed per patient, each containing both calcified and non-calcified components. Quantitative measurements were performed in calcified plaque across energy levels from 40 to 120 keV and comprised attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), corrected image noise (CIN) and artifact index (AIX). Two radiologists independently rated image quality, artifacts, and diagnostic assessability of both components using five-point scales. Results: Attenuation and CNR were highest at 40 to 50 keV, where CIN and AIX were also greatest. SNR followed a U-shaped course, lowest at 90 keV and highest at 110 to 120 keV, where intraluminal attenuation was too low for reliable luminal delineation. Reader ratings were highest at 40 to 50 keV for non-calcified components and at 70 to 80 keV for calcified plaque, with good interobserver agreement throughout (κ 0.74 to 0.92). After correction for multiple testing, adjacent energy levels were frequently indistinguishable. Conclusions: Optimal PCCT VMI energy levels depend on plaque composition. The findings support implementing standardized protocols with automatic dual-range reconstructions (40–50 keV and 70–80 keV) to enable efficient, individualized carotid plaque assessment in clinical practice.

Read PDF

Similar papers

Open access Sep 2026

Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging

Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retr...

Andreea I. Nica, C. Booz, G. Bucolo et al. · 0 citations
Sep 2026

Photon-counting detector CT with virtual monoenergetic imaging and iterative metal artifact reduction for spinal fusion implants: optimal keV and combined benefits.

OBJECTIVES To evaluate the effectiveness of virtual monoenergetic imaging (VMI) and iterative metal artifact reduction (iMAR), alone and in combination, for reducing metal artifacts in postoperative CT scans of patients with spinal fusion, using a clinical photon-counting detector CT (PCD-CT) system. MATERIALS AND ME...

Xin-Ying Huang, Zai-Zhu Zhang, Yong An et al. · 0 citations

Current Medical Imaging

Xing-Lu Li, Xing-Yu Chen, Wen Chen et al. · 0 citations
Sep 2026

Quantitative Comparison of Virtual and True Noncontrast Lung Images in Photon-counting CT: Global and Regional Attenuation Assessment.

Background Use of virtual noncontrast (VNC) images from photon-counting CT (PCCT) may reduce radiation dose and support quantitative lung analysis by obviating the need for separate true noncontrast (TNC) acquisitions. Their accuracy for lung densitometry, however, has not been systematically assessed. Purpose To evalu...

Max L. Bodlien, S. Scharm, A. Hunkemöller et al. · 0 citations
Open access Aug 2026

Study on the combined application of selected virtual monoenergetic imaging, virtual non-contrast imaging, and adaptive statistical iterative reconstruction-V in head and neck CT angiography using 256-slice wide-body CT

Objective To evaluate the value of combining spectral CT-derived virtual monoenergetic imaging, adaptive statistical iterative reconstruction-V (ASIR-V), and virtual non-contrast imaging in head and neck CT angiography (CTA) for patients with cerebrovascular disease (CVD). Methods 150 patients undergoing head and neck...

Wen-Chao Li, Pei-Heng Li, Qiang Li et al. · 0 citations
Open access Aug 2026

Coronary Artery Calcium Scoring with Photon-Counting Detector CT: Ultra-Low-Dose Scan Versus Coronary CT Angiography-Derived Images.

PURPOSE To compare coronary artery calcium (CAC) scores from ultra-low-dose true non-contrast (TNC), virtual non-contrast (VNC), and virtual non-iodine (VNI) images with standard TNC on a dual-source photon-counting detector CT (PCD-CT). METHODS In this prospective single-center study (January 2025-March 2026), patie...

S. Araki, S. Nakamura, M. Deguchi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.