Sep 2026· Zaria Journal of Electrical Engineering Technology· 0 citations
Abstract
Voltage instability remains a major operational challenge in large-scale transmission networks, particularly in developing power systems with increasing load demand. This paper proposes a coordinated on-load tap changer (OLTC) control strategy based on a Hybrid Particle Swarm Optimization–Grey Wolf Optimization (HPSOGWO) algorithm to enhance voltage stability and power quality. The proposed approach is validated on a practical Nigerian 56-bus, 330-kV transmission network using real system data obtained from the Oshogbo National Control Centre. Simulation results demonstrate that the proposed scheme restores all bus voltages within IEEE-recommended limits, achieving a 76.47% reduction in voltage deviation. In addition, active power deviation and reactive power loss are reduced by approximately 87% and 90%, respectively. Injection current analysis confirms balanced current distribution and safe system operation. The results validate the effectiveness and practical feasibility of the proposed HPSOGWO-based OLTC coordination scheme for real-world transmission networks.
The increasing complexity of modern electrical networks, driven by the expansion of transmission networks along with the increasing penetration of renewable-based generation, has intensified concerns regarding voltage control performance and rotor-angle stability. Flexible AC transmission system (FACTS) technology, par...
Makhlouf Chouki, H. Zaimen, H. Belila· International Journal of App...· 0 citations
The increasing integration of renewable energy sources, especially solar photovoltaic (PV) systems, poses challenges such as voltage fluctuations and power quality issues in modern power networks. Reactive power support has become an effective solution to enhance voltage stability and minimize system losses. This study...
Aminudin Anuar, Wan Muhamad Afnan Wan Azli, C. Wooi· Advanced and Sustainable Tec...· 0 citations
High penetration of distributed photovoltaic generation can cause simultaneous
overvoltage, undervoltage, and increased voltage fluctuations in distribution feeders. This
study proposes a voltage-quality-assessment-based strategy for coordinating the configuration and
operation of step voltage regulators.
An...
Wen-Jie Sun, Shu-Bao Zheng, Jin-Nian Yang et al.· Recent Advances in Electrica...· 0 citations
In recent years, wind power generation has attained significant attention, leading to the
installation of numerous wind power plants worldwide. Most wind turbines employ
induction generators, which typically absorb substantial reactive power (VARs) from the
grid. This reactive power demand can result in voltage drops a...
K. Archana, V. Pushparajesh· ITEGAM- Journal of Engineeri...· 0 citations
The increasing penetration of nonlinear loads and distributed generation (DG) in distribution networks poses significant challenges to voltage regulation and power loss minimization. Although Unified Power Quality Conditioner (UPQC), has proven effective in enhancing power quality and system stability, determining its...
M. Mustapha, Mustapha Kunduli, Babangida Modu et al.· Zaria Journal of Electrical...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.