Skip to content
Open access

Experimental Investigation of Voltage and Air Velocity Effects on Sustainable Thermoelectric Air Conditioning

Aug 2026 · Energies · 0 citations

Abstract

Thermoelectric air conditioning (TEAC) systems are gaining attention as refrigerant-free, solid-state cooling technologies due to their compactness, low noise, and environmental benefits. However, their widespread application is constrained by low energy efficiency and the limited experimental understanding of the coupled influence of electrical and aerodynamic operating parameters. Most existing studies address thermoelectric cooling under isolated conditions or rely on theoretical modeling, leaving a clear gap in the experimental quantification of the interactive effects of applied voltage and air velocity on system performance. To address this gap, the present study experimentally investigates a laboratory-scale TEAC system equipped with four thermoelectric cooler (TEC) modules (model TEC1-12706). The system was tested under controlled conditions by varying the input voltage from 6 to 12 V and the air velocity from 1 to 3 m/s. Key performance indicators, including cooling capacity, power consumption, cold-side temperature, and coefficient of performance (COP), were systematically measured and analyzed. The results show that increasing the applied voltage from 6 to 12 V enhances cooling capacity by approximately 50.4%, while significantly increasing electrical power consumption, leading to a 59% reduction in COP due to intensified Joule heating. Conversely, increasing air velocity improves convective heat transfer, resulting in a COP enhancement of about 24% with relatively stable power input. The findings highlight a clear trade-off between cooling capacity and energy efficiency and identify a practical operating region for balanced TEAC performance.

Read PDF

Similar papers

Open access Sep 2026

Experimental Assessment of the Effect of Reference Surface Temperature on Auxiliary Energy Consumption in a Thermoelectric-Based Battery Thermal Management System

Thermoelectric coolers (TECs) have attracted considerable attention for battery thermal management owing to their compact structure, precise temperature control capability, and ease of integration. However, the influence of reference surface temperature on the auxiliary energy consumption of TECs remains insufficiently...

Erdoğan Güner · 0 citations
Open access Sep 2026

Comprehensive Constraint Optimization of Thermoelectric Modules for Cooling Applications

Thermoelectric air conditioners (TEACs) are a solid-state technology with the potential to replace conventional vapor compression-based air conditioning. This technology converts electrical power into a cooling/heating heat flux using the thermoelectric effect. TEACs are used in microelectronic, medical, and sensor i...

Byron Castillo, Abhishek Saini, Sarah J. Watzman · 0 citations
Open access Sep 2026

COOLING LOAD IMPACT ON THE PERFORMANCE OF A PORTABLE THERMOELECTRIC REFRIGERATOR

This study investigates the influence of cooling load on the performance of a portable thermoelectric refrigerator based on the Peltier effect. A compact refrigeration system using a TEC1-12710 thermoelectric module powered at 12 V DC was experimentally analyzed under varying cooling loads, heatsink configurations, and...

Ghulam Raza Shah Rizvi, Rahool Rai, Claudia Săvescu · 0 citations
Open access Sep 2026

Investigation of the Heating Performance of a Solar-Assisted Inter-Cooling Air Source Heat Pump System

This paper proposes a novel solar-assisted inter-cooling air source heat pump (SCAS–HP) system that integrates a solar collector/evaporator into the intermediate injection branch to utilize solar energy for increasing the refrigerant flow rate at intermediate pressure. A numerical model of the system was developed and...

S. Duan, Chang-Yan Huang, Xin Zhang · 0 citations
Open access Aug 2026

Investigation and Feasibility Analysis of Earth Tube Heat Exchangers (ETHE) for Sustainable Building Thermal Conditioning

With escalating global energy demands and rising ambient temperatures driven by climate change, active heating, ventilation, and air-conditioning (HVAC) systems constitute a massive fraction of primary electrical consumption and direct greenhouse gas emissions via high Global Warming Potential (GWP) chemical refrigeran...

Ajay Kumar, Ranjeet Kumar, Madhuri Kumari et al. · 0 citations
Open access Sep 2026

EXPERIMENTAL PERFORMANCE EVALUATION AND FEASIBILITY ASSESSMENT OF THERMOELECTRIC WATER HEATING SYSTEMS FOR LOW-VOLTAGE DC APPLICATIONS

Water heating is among the most energy-consuming operations in residential and industrial setups, prompting the development of alternative, sustainable, and efficient methods of heating. This paper experimentally evaluates the operational performance of a low-voltage DC-powered thermoelectric water heating unit utilizi...

Patrick Effraima, Bismark Budu, Micheal Mensah et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.