During the construction process of prefabricated helical anchor foundations, eccentricity and inclined installation of anchor rods may alter the stress distribution and interfacial load-transfer mechanism within the UHPC grouting connection zone, resulting in the inability of performance evaluation methods established under ideal installation conditions to fully capture the joint response under actual construction scenarios. In this study, five full-scale pullout tests and three-dimensional nonlinear finite element analyses were conducted to investigate the load-transfer behavior, damage evolution process, and failure modes of UHPC-grouted helical anchor-prefabricated cap connection joints subjected to construction deviations. The results demonstrate that eccentricity primarily induces local stress redistribution and has a limited influence on the bearing capacity, whereas inclination introduces additional bending moments that accelerate the initiation of interfacial damage. With the incorporation of shear keys, the damage-control load under non-eccentric conditions increased from 429 kN to 800 kN, representing an enhancement of approximately 86.5%. Based on the experimental and analytical results, a pullout performance evaluation method considering interfacial load-transfer characteristics and the influence of construction deviations was proposed. The maximum error was 7.5% under the single eccentricity condition and 18.0% under the combined eccentricity-inclination condition. The findings provide valuable references for the design optimization and performance evaluation of prefabricated helical anchor foundation connection joints under non-ideal construction conditions.
Carbon fiber-reinforced polymer (CFRP) driveshafts offer significant lightweight potential, but the performance of pin-loaded joints is strongly affected by laminate architecture. To support laminate selection beyond peak strength alone, a numerical screening framework combining finite-element analysis, Hashin-based pr...
Li-Ming Zheng, Lin Yuan, Neng Wang et al.· Polymers· 0 citations
Four full-scale exterior beam-to-column connections comprising H-section beams and square hollow-section (SHS) columns were tested under low-cycle reversed loading to investigate two engineering-oriented T-stub section configurations and the effects of the presence or absence of triangular stiffeners. Failure modes, mo...
Xin Bu, Jia Fan, Yi-Fei Chen et al.· Buildings· 0 citations
This study evaluates the structural behavior of hybrid bolted beam-to-beam connections for precast reinforced-concrete members through coupled testing and nonlinear simulation. Six full-scale assembled beams were tested in monotonic four-point bending, with three anchor-bolt diameters (16, 20, 24 mm) and two assembly c...
Wael Hameedi, I. Völgyi· Materials Structure· 0 citations
Basalt fiber-reinforced polymer (BFRP) offers the advantages of high strength, excellent corrosion resistance, and low weight, providing a promising material solution to the durability problems associated with conventional steel anti-floating anchors. However, a systematic understanding of the interfacial bonding behav...
Carbon fiber reinforced polymer (CFRP), as an anisotropic material, poses significant challenges to the design and performance of anchorage systems. In this study, a planar clamping anchorage (PCA) applicable to multi‐layer CFRP plate cables is first developed, and corresponding design methods for key components are...
This study investigates the structural response of cellular steel frames, with particular emphasis on the influence of frame stiffness on failure mechanisms and load redistribution. Two steel portal frame specimens were experimentally tested under concentrated mid-span loading: a conventional solid-web frame (S01) and...
W. M. Sayed, Ali Hammad, S. K. Hassan· Scientific Reports· 0 citations