Native myocardial T1 mapping using rapid 1.5T T1FLASH and T1 MOLLI during breath-hold and free-breathing

Sep 2026 · BMC Cardiovascular Disorders · Vol 26 · 0 citations · 50 references
Medicine

Abstract

Quantitative myocardial T1 mapping is an established technique in cardiovascular magnetic resonance (CMR). However, conventional T1 mapping requires relatively long breath-holds (BH), which may lead to breathing artifacts and reduced image quality in patients with limited BH capacity. The T1 fast low angle shot (T1FLASH) sequence enables myocardial T1 mapping with shorter BH durations. In this prospective study, 14 healthy adult volunteers (8 female; mean age 27 ± 4 years) underwent myocardial T1 mapping at 1.5 T using modified Look-Locker inversion recovery with motion correction (T1 MOLLI MOCO) and rapid T1FLASH. Both sequences were acquired during BH and free breathing (FB). Global and segmental myocardial T1 values and image quality were assessed. Interrater, intrarater, and interstudy reproducibility were evaluated. Comfort was assessed using a questionnaire. Statistical analysis included the Shapiro-Wilk test, paired t-test, Pearson correlation, Bland-Altman analysis, intraclass correlation coefficient, Wilcoxon signed-rank test, and Spearman rank correlation (p < 0.05). BH duration was significantly shorter with rapid T1FLASH compared with T1 MOLLI MOCO (3–4 s vs. 12–14 s), and participant comfort was higher with rapid T1FLASH (p < 0.05). During BH, global myocardial T1 values were significantly higher with rapid T1FLASH (1030 ± 35 ms) than with T1 MOLLI MOCO (1000 ± 26 ms; p < 0.01). The slightly increased variability observed with rapid T1FLASH remained below diagnostically relevant thresholds (4% error margin). Both techniques showed moderate-to-good correlation for global T1 values (r = 0.63; p < 0.01). Rapid T1FLASH demonstrated good image quality that was comparable for clinical interpretation during BH, although T1 MOLLI MOCO received slightly higher qualitative image scores. During FB, variability of global and segmental T1 measurements increased significantly, with apical segments being more and AHA segments 2 (basal anteroseptal), 5 (basal inferolateral), 8 (mid anteroseptal), 11 (mid inferolateral) less affected by respiratory artifacts. Interrater, intrarater, and interstudy reproducibility were good to excellent. Rapid T1FLASH demonstrated good agreement with conventional T1 MOLLI MOCO and reproducible myocardial T1 measurements, with substantially reduced BH duration while maintaining good image quality. These findings support further evaluation of rapid T1FLASH as an alternative T1 mapping approach in patients with limited BH capacity. Conventional T1 MOLLI MOCO remains the preferred technique when adequate BH can be achieved.

Read PDF

Similar papers

Open access Oct 2026

Water-T1, PDFF, and T2* mapping of the liver using chemical shift-encoded MOLLI.

PURPOSE Hepatic MRI T1 relaxation time is a putative measure of fibrosis and inflammation but may be confounded by hepatic fat. This study evaluated a chemical shift-encoded Modified Look-Locker Inversion Recovery (CSE-MOLLI) technique for simultaneous water-specific T1 (water-T1), proton density fat fraction (PDFF), a...

Amol Pednekar, Joshua S. Greer, Pradipta Debnath et al. · 0 citations
Open access Aug 2026

Simultaneous 3‐D Adiabatic T1ρ, T2*, and Quantitative Susceptibility Mapping for Characterization of Myocardial Infarction in Ex Vivo Mouse

To develop a T1ρ‐weighted quantitative susceptibility mapping (QSM) technique for simultaneous imaging of T1ρ and T2* relaxation and magnetic susceptibility in ex vivo mouse hearts after myocardial infarction (MI). MI was induced in C75Bl/6JOlaHsd mice, and their hearts (nMI = 7, nCTRL = 6) were imaged ex vivo by combi...

Iida Räty, O. Nykänen, S. Kettunen et al. · 0 citations
Open access Aug 2026

Pre-Scan Breathing Pattern and Image Quality in Respiratory-Triggered T2-Weighted Liver MRI: Radial Versus Cartesian Fast Spin Echo.

BACKGROUND Respiratory-triggered T2-weighted imaging (T2WI) may use rectilinear sampling (respiratory-triggered fast recovery fast spin echo [RT-FRFSE]) or radial sampling (periodically rotated overlapping parallel lines with enhanced reconstruction [PROPELLER]). Their relative performance across breathing patterns is...

H. Park, Jimi Huh, K. Lee et al. · 1 citation
Open access Oct 2026

From Breath-Hold to Free-Breathing: Possibilities in High-Resolution Quantitative Susceptibility Mapping (QSM) of the Kidney With Respiratory Gating.

PURPOSE This study aimed to assess the feasibility of QSM in the human kidney during free-breathing using respiratory gating for motion compensation. METHODS Renal imaging of 15 healthy volunteers was performed using an axial multi-echo GRE sequence on a 3 T MRI scanner. Each subject was scanned once during breath-ho...

Matthias Deitermann, Birte Sehlmeyer, T. Thiel et al. · 0 citations
Review Open access Aug 2026

Technical challenges in establishing local native T1 reference ranges in cardiac MRI: a critical review

Standardization of T1 mapping protocols is needed to improve the comparability and reliability of myocardial T1 values across CMR centers, and proposals for mitigation, harmonization, and standardization strategies designed to enhance comparability across CMR platforms are reviewed.

Maheran Che Ha, K. A. Sayuti, Y. Mohammed et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.