Simulation-embedded reconstruction enabled integrated physical modeling within iterative reconstruction and improved the agreement with ideal reference images under controlled phantom-based conditions and supported the technical feasibility and basic validity of acquisition-consistent Monte Carlo-embedded reconstruction for myocardial SPECT.
Abstract
Objective
To implement and technically validate a simulation-embedded maximum likelihood expectation-maximization (S-MLEM) framework for myocardial single-photon emission computed tomography (SPECT) that uses the simulation of imaging nuclear detectors (SIMIND) Monte Carlo code as a forward projector for integrated modeling of attenuation, scatter, and resolution degradation.
Methods
SIMIND was configured to model a clinical SPECT system and an HL-type myocardial phantom. Agreement between the measured and simulated data was assessed using energy spectra, projection and short-axis images, normalized mean squared error (NMSE), and structural similarity index (SSIM). The validated model was incorporated into S-MLEM. Correction performance was evaluated using simulated four-sphere phantom data and three independent HL-type phantom acquisitions. The uncorrected MLEM and S-MLEM images were compared with ideal references obtained from SIMIND without attenuation, scatter, collimator blurring, or statistical noise. The evaluation included profiles, NMSE, SSIM, and myocardial count uniformity, expressed as the coefficient of variation (CV) of the polar-map values.
Results
SIMIND closely reproduced the measured data. In a four-sphere phantom, S-MLEM improved deep-source count recovery, reduced superficial shape distortion, and restored isotropy. In the HL-type myocardial phantom, S-MLEM improved basal and inferior wall depiction, sharpened the myocardium-cavity interface, reduced cavity spill-in, increased SSIM, and reduced NMSE. Polar map CV decreased from 12.77 ± 0.30% with uncorrected MLEM to 6.48 ± 0.32% with S-MLEM, approaching the ideal reference value of 5.70%.
Conclusion
Simulation-embedded reconstruction enabled integrated physical modeling within iterative reconstruction and improved the agreement with ideal reference images under controlled phantom-based conditions. These findings supported the technical feasibility and basic validity of acquisition-consistent Monte Carlo-embedded reconstruction for myocardial SPECT and provided a basis for further evaluation under more realistic and clinical conditions.
A practical commissioning workflow to optimize ¹⁷⁷Lu SPECT/CT imaging across different commercial scanner–reconstruction configurations is developed and a practical framework for local ¹⁷⁷Lu SPECT/CT optimization is provided.
L. Lampertico, G. Muti, C. Carbonini et al.· Advances in Radiotherapy &a...· 0 citations
Accurate modelling and performance evaluation of gamma-ray scintillation detectors are required in single photon emission computed tomography (SPECT) systems to ensure reliable nuclear medicine diagnostics. Monte Carlo simulation is therefore a powerful computational technique used to accurately model the gamma-ray sci...
Zhi-Qiang Peng, Muhammad Abdul Wasaye, Irfan Siddique et al.· EJNMMI Physics· 0 citations
OBJECTIVE
To perform a comprehensive comparative analysis of proton, helium-ion, and carbon-ion computed tomography (CT) as direct imaging modalities for hadron therapy treatment planning, focusing on Relative Stopping Power (RSP) reconstruction accuracy and patient radiation dose. Approach: High-fidelity Monte Carlo s...
Z. Jólesz, G. Bíró, G. Papp et al.· Physics in Medicine and Biol...· 0 citations
Open-source BSREM showed task-, region, and count-dependent behavior, supporting task- and count-specific parameter selection before clinical application, and showed reduced left-putaminal uptake remained underestimated, and putaminal asymmetry moved further from their theoretical values.
Takuro Shiiba, Shingo Tanahashi, Kohei Takasu et al.· Physical and Engineering Sci...· 0 citations
Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated fr...
Yu-Hao Wang, Zhen-Dong Zhang, E. R. Criscuolo et al.· 0 citations
This study investigated the relationship between body size, administered activity, and image quality (IQ) using two patient-like phantoms representing normal and obese body profiles, and demonstrated the count rate capabilities up to and beyond the saturation limit.
Nanna Overbeck, Zuzanna Czeluśniak, Søren Holm et al.· Physics in Medicine and Biol...· 0 citations