High-voltage circuit breaker fault detection based on improved complete ensemble empirical mode decomposition with adaptive noise and firefly algorithm-optimized least squares support vector machine
Sep 2026· European Conference on Electrical Engineering and Computer Science· Vol 14327, pp. 143271W - 143271W-9· 0 citations· 15 references
Engineering
TL;DR
The experimental results demonstrate that the proposed novel method for fault detection based on the Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise and the Firefly Algorithm has strong theoretical and engineering application value for high-voltage circuit breaker fault detection.
Abstract
To address the challenges of difficulty in extracting fault features and low detection accuracy for high-voltage circuit breakers, this study proposes a novel method for fault detection based on the Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (ICEEMDAN) and the Firefly Algorithm (FA) optimized Least Squares Support Vector Machine (LSSVM) for high-voltage circuit breaker fault detection. First, the ICEEMDAN method is used to process the circuit breaker vibration signals, decomposing them into a series of intrinsic mode function (IMF) components. The energy entropy of the obtained IMF components is calculated as the fault feature vector of the circuit breaker. To address the issue of high-dimensional fault feature vectors, kernel principal component analysis (KPCA) is employed for dimensionality reduction and feature selection. The selected features are then used for fault detection via the LSSVM method. To address the issue of the significant impact of the core parameters on the classification performance of the LSSVM method, FA is employed for parameter optimization to determine the optimal parameter combination, and an FA-LSSVM fault detection model is established. Test set samples are input into the FA-LSSVM model for fault detection. Experimental results show that the fault detection accuracy of the proposed method for high-voltage circuit breakers reaches 99.17%. To validate the effectiveness of the proposed method, it is compared with the particle swarm optimization algorithm (PSO) and dung beetle optimization (DBO) algorithms. The proposed method achieves a fault detection accuracy rate that is 3.34% higher than the PSO-LSSVM method and 2.5% higher than the DBO-LSSVM method. The experimental results demonstrate that the proposed method has strong theoretical and engineering application value for high-voltage circuit breaker fault detection.
Comparative results demonstrate that FFT-based feature extraction combined with Random Projection (RP) provides the most effective feature representation, while the proposed NATS classifier achieves binary classification accuracies exceeding 92% across all operating scenarios.
S. Udomsuk, Rangsarit Vanijirattikhan, S. Khomsay et al.· Energies· 0 citations
The vibration signal is composed of impact sub-waves generated by friction and collision among mechanical components during the operating process of the circuit breaker. It contains key operational information such as spring energy release, mechanical transmission, closing latch, and braking. This paper proposes a circ...
Hai-Wang Jin, Hai-Qing An, Tian-Qi Li et al.· European Conference on Elect...· 0 citations
This paper presents a methodology for diagnosing and monitoring open-circuit faults in IGBT switches within inverter–induction motor systems using current signal analysis. The method integrates Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (ICEEMDAN) for signal processing and the Random Fo...
B. D. E. Cherif, Sara Seninete, H. Rahali et al.· Metrology and Measurement Sy...· 0 citations
As critical equipment in power systems, the reliable operation of power transformers is directly linked to the overall safety of the power grid. Traditional fault diagnosis methods based on dissolved gas analysis generally rely on a single gas feature, which inevitably causes misjudgment and suffers from inadequate acc...
Shuang Wang, Yuen Wen, Jun-Wei Yao et al.· Energies· 0 citations
Accurate and timely detection of faults in power systems is critical for ensuring operational reliability and safety. This study proposes a machine learning based fault detection framework that utilizes statistical features extracted from voltage and current time series signals. Each sample consists of one current row...
Javed Hossain, Yu-Hao Li, Hui Liu et al.· 2026 6th Power System and Gr...· 0 citations
In response to the serious noise interference in the fault signals obtained by the vibration sensors and the difficulty in effectively extracting the fault characteristics, a rolling bearing fault diagnosis method based on adaptive modal decomposition and correlation kurtosis feature enhancement is proposed. This met...