The results demonstrate that the proposed hybrid materials combine thermal stability, bioactivity, and cytocompatibility, highlighting their potential as bioactive coatings for biomedical applications.
Abstract
The development of bioactive hybrid coatings for biomedical implants requires materials exhibiting suitable thermal stability, bioactivity, and biocompatibility. In this study, hybrid organic–inorganic sol–gel coatings based on silica (SiO2) and polyethylene glycol (PEG, 24 wt%) were functionalized with different concentrations of caffeic acid (CafA 5, 10, and 15 wt%) and deposited onto AISI 304 and AISI 316 stainless steel substrates by dip-coating without surface pre-treatment. The proposed approach enabled the formation of homogeneous hybrid coatings on untreated stainless steel substrates through a simple and scalable deposition process. A thermal analysis demonstrated the stability of the hybrid network and the effective integration of the organic and inorganic phases. Bioactivity was evaluated by in vitro immersion in simulated body fluid (SBF), while SEM observations revealed the formation of mineral deposits on the coating surface, and an EDX analysis confirmed the presence of calcium and phosphorus within the deposited layer. The formation of crystalline hydroxyapatite (HA) was subsequently confirmed by X-ray diffraction (XRD), confirming that all investigated formulations retained their ability to induce apatite formation after SBF immersion. In addition, in vitro biocompatibility assays confirmed that the developed materials exhibited concentration-dependent cytocompatibility, with the cellular response being influenced by the amount of incorporated CafA. Overall, the results demonstrate that the proposed hybrid materials combine thermal stability, bioactivity, and cytocompatibility, highlighting their potential as bioactive coatings for biomedical applications.
The chemical similarity and bioactivity of HAp with the mineral phase of natural bone make HAp-based surface engineering an interesting area for study on enhancing the biological function and interfacial performance of orthopedic implants. This review critically revises the HAp-based composite systems and surface engin...
Stainless steel 316L is widely used for biomedical implants because of its high mechanical strength, corrosion resistance, and durability; however, its relatively bioinert surface requires modification to improve biological interaction and osseointegration. In this study, multifunctional Ag/PMMA–NiO multilayer coatings...
Duaa S. Al-khafajy, Hanaa A. Al-kaisy, Mohanad N. al-Shroofy et al.· Experimental and Theoretical...· 0 citations
Problem. Hydroxyapatite (HA, chemical formula Ca10(PO4)6(OH)2) is widely used as a biocompatible and
bioactive ceramic due to its structural and chemical similarity to the main mineral component of human hard tissues.
A disadvantage of hydroxyapatite is its low mechanical properties (strength, crack resistance, and imp...
V. Rubanik, D. Bahrets, S. Mozzharov et al.· Frontier Materials & Tec...· 0 citations
Background316L stainless steel (SS) is widely used in biomedical implant applications because of its excellent mechanical properties, corrosion resistance, biocompatibility, and cost-effectiveness. However, its long-term performance in physiological environments is limited by localized corrosion, ion release, and inade...
M. Priyan, G. Godwin· Bio-medical materials and en...· 0 citations