AI-Enabled Condition Monitoring for Predictive Maintenance and Early Anomaly Detection in Renewable-Rich Electric Distribution Systems: A simulation-based proof-of-concept study using the IEEE 33-bus feeder

Aug 2026 · Review of Applied Science and Technology · Vol 16, pp. 01-07 · 0 citations

TL;DR

The findings support the use of feeder physics, temporal feature engineering, and ensemble learning for condition monitoring, while also showing that deployment-oriented predictive maintenance will require field data, higher-fidelity failure models, and explicit adaptation to unseen DER operating regimes.

Abstract

High penetration of distributed energy resources (DERs) increases the operating variability of distribution systems and complicates the separation of normal renewable-driven changes from developing equipment and network abnormalities. This study presents a reproducible simulation-based condition-monitoring framework intended to support predictive-maintenance research in a renewable-rich radial distribution network. The IEEE 33-bus feeder is solved with a backward-forward sweep load-flow model under stochastic load variation and DER penetration. Four operating classes are generated: normal operation, progressive line-resistance degradation, localized overload, and source-voltage reduction. Each 20-step observation window contains 68 electrical features comprising bus-voltage magnitudes, branch-current magnitudes, net active/reactive power, and feeder losses. Temporal statistical descriptors are used with Random Forest, radial-basis-function support vector machine (RBF-SVM), and HistGradientBoosting classifiers. On an in-distribution (IID) test set, HistGradientBoosting achieved 90.75% accuracy and 90.75% macro-F1, outperforming Random Forest and RBF-SVM. Under a high-DER stress test with 50–70% DER penetration, performance decreased to 83.50% accuracy and 83.58% macro-F1, indicating useful but imperfect generalization. Progressive line degradation was the most difficult condition to distinguish from normal operation, whereas all 100 source-voltage-reduction samples were correctly classified in the simulated IID test set. The findings support the use of feeder physics, temporal feature engineering, and ensemble learning for condition monitoring, while also showing that deployment-oriented predictive maintenance will require field data, higher-fidelity failure models, and explicit adaptation to unseen DER operating regimes.

Read PDF

Similar papers

Review Open access Sep 2026

Predictive Maintenance of High-Voltage GIS Assets for Saudi Smart Grids: Using Partial Discharge Monitoring, Equipment Diagnostics, and Failure-Risk Assessment under Vision 2030

- High-voltage gas-insulated switchgear (GIS) is central to compact, reliable transmission substations, yet its apparent reliability can conceal insulation defects, mechanical degradation, gas-system anomalies, thermal problems, and ageing mechanisms that become costly when detected only after failure. This review deve...

Faisal Aleem · 0 citations
Open access Sep 2026

Faulty Feeder Identification for Single-Phase-to-Ground Faults in Small-Current Grounded Systems Based on an Adaptive Transient Window and Robust Multi-Feeder Graph Consistency

Accurate faulty feeder identification is essential for the safe operation of small-current grounded distribution networks under single-phase-to-ground faults, yet existing transient-based methods often rely on preset data windows and insufficiently exploit the collective consistency of healthy feeders. This study propo...

Jia-Xing Yu, Hong-Qi Zhang, Zhuo Jiang · 0 citations
Open access Sep 2026

Mechanism–Data Dual-Driven Outage Identification Framework for Distribution Networks with High Penetration of Inverter-Based Distributed Generation

INTRODUCTION: High penetration of inverter-based distributed generators (IBDGs) changes power-flow patterns and fault transients in distribution networks, reducing the effectiveness of conventional outage identification. Under the adopted low-voltage ride-through control model, IBDG fault currents are limited to 1.2–1....

Ning Liu, Xiao-Peng Zhang, Xu-Dong Wang et al. · 0 citations
Open access Sep 2026

Advanced data driven models based on machine learning for detection of faults and failures in solar based renewable energy systems

A novel framework that integrates Extended Kalman Filter (EKF) state estimation with uncertainty-aware graph learning for photovoltaic (PV) array fault detection and localization and demonstrates strong robustness to sensor noise and transient faults by leveraging physical uncertainty to guide graph topology.

Saud Wasly, N. Abu-Hamdeh · 0 citations
Preprint Sep 2026

Reliability Value of Long-Duration Energy Storage against Extreme Events in High-Renewable Grids: A Full-Year AC-OPF Assessment

Long-duration energy storage (LDES) can mitigate prolonged renewable--load imbalances during Dunkelflaute events, but existing studies rely on zonal or linearized DC network models and inadequately analyze the operational feasibility of the grid across a wide range of full-year renewable, load, and contingency scenario...

Jeongdong Kim, Jonggeol Na, Sung-Ho Shin · 0 citations
Open access 2026

Risk-Aware Multi-Timescale Scheduling and Distributed Event-Triggered Control for Overload Mitigation in PV-Rich Distribution Networks

: High-penetration distributed photovoltaic (PV) integration improves renewable utilization in distribution networks, but abnormal PV ramps may also be transformed into feeder active-power overloads when coupled with load variation and feeder power-flow baselines. To address this issue, this paper proposes a risk-aware...

Guang-Yuan Xu, Wei Wang, Biao Shi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.