Skip to content
Open access

The accuracy of pedicle screw placement in thoracolumbar fractures: A comparative study of automated cone-beam CT-based navigation and conventional fluoroscopy

Sep 2026 · Brain and Spine · Vol 6 · 0 citations · 27 references
Medicine

TL;DR

Automated CBCT-based intraoperative 3D navigation provides high pedicle screw accuracy and comparable perioperative outcomes between automated CBCT-based navigation and conventional fluoroscopy in thoracolumbar fracture fixation.

Abstract

Introduction Pedicle screw fixation is a standard technique for stabilizing unstable thoracolumbar fractures. Mobile cone-beam CT (CBCT) systems with robotic image acquisition enable automated navigation workflows, but clinical data in spine trauma remain limited. Research question To compare pedicle screw accuracy and perioperative outcomes between automated CBCT-based navigation and conventional fluoroscopy in thoracolumbar fracture fixation. Material and methods This single-centre retrospective cohort study included adults with unstable thoracolumbar spine injuries undergoing pedicle screw fixation during a 5.5-year period. In the CBCT group, intraoperative 3D navigation was performed using an automated CBCT system. Perioperative and postoperative variables were recorded, and screw placement was assessed using the Gertzbein–Robbins classification. Outcomes were compared between groups. Results Forty-six patients were included: 25 treated with automated CBCT-based navigation and 21 with conventional fluoroscopy. Among 313 evaluable screws, 96.8% were graded Gertzbein–Robbins A or B, and no grade E breaches were observed. In CBCT screws, no grade D or E breach occurred, and no screw-related early reoperations were required. Total operative time was longer with CBCT (154 vs. 119 min; p = 0.018), and blood loss was numerically higher (259 vs. 179 mL; p = 0.272), although operative time and blood loss per pedicle screw did not differ significantly between groups. Length of hospital stay and early clinical outcomes were comparable. Conclusion Automated CBCT-based intraoperative 3D navigation provides high pedicle screw accuracy and comparable perioperative outcomes. CBCT-based navigation enables real-time 3D visualization and intraoperative verification, supporting its role as a reliable imaging modality in spine trauma surgery.

Read PDF

Similar papers

Open access Aug 2026

Accuracy of pedicle screw fixation under O-arm and navigation guidance in thoracolumbar spine surgery

Background: Accurate pedicle screw placement is critical for successful thoracolumbar spine fixation. Misplacement can lead to complications such as neurological injury, vascular damage, and the need for revision surgeries. The use of 3D intraoperative imaging and navigation systems, such as the O-arm and Stealth syste...

R. Gupta, Swaroop Patel, A. K. Jha et al. · 0 citations
Open access Sep 2026

The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.

STUDY DESIGN Retrospective comparative cohort study. INTRODUCTION Accurate pedicle screw placement is critical for spinal stability and for preventing neurological or vascular injury. This study compared screw-placement accuracy and safety between robot-assisted and navigation-guided pedicle screw implantation and ex...

Ali Mulhem, Lennart Schreiweis, H. Krenzlin et al. · 0 citations
Review Sep 2026

3D-Printed Guides, Navigation, and Robotic Assistance in Spinal Instrumentation: A Network Meta-Analysis of Pedicle Screw Accuracy and Clinical Outcomes.

BACKGROUND Accurate pedicle screw placement is essential to prevent neurovascular injury, revision surgery, and excess healthcare costs. While navigation and robotic systems enhance accuracy over freehand or fluoroscopic techniques, they remain limited by high cost and patient radiation exposure. Three-dimensional prin...

Shehab Eid, Navid Ghaderi, R. Koucheki et al. · 0 citations
Review Open access Sep 2026

Intraoperative Accuracy of Sacroiliac Joint Fusion Implant Placement Using 3D Computed Tomography-Guided Imaging for Primary Sacroiliac Arthropathy.

BACKGROUND Placement of iliosacral screws is technically challenging. This is especially the case with dysmorphic anatomy. Intraoperative computer navigation can be used to facilitate. No studies have evaluated computer navigation accuracy for minimally invasive sacroiliac joint (SIJ) fusion using iliosacral screws. We...

Vasil Kukushliev, Jason J. Haselhuhn, Chad Byrnes et al. · 0 citations
Open access Aug 2026

3D-printed patient-specific guides improve screw accuracy in upper cervical spine surgery: a comparative study

Objective To evaluate the feasibility and clinical efficacy of patient-specific 3D-printed guide plates for pedicle screw placement in the upper cervical spine, compared with the conventional free-hand technique. Methods A retrospective analysis was conducted on 39 patients who underwent upper cervical spine surgery be...

Guo-Qi Niu, Ya-Long Guo, Gong Zhou et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.