Skip to content
Open access

ILLUSTRATIVE DATA VERSION — NOT FOR SUBMISSION Accuracy and Passive Fit of Digital versus Conventional Impression Techniques for Full-Arch Implant-Supported Prostheses: A Comparative In Vitro Study

Aug 2026 · Libyan journal of medical research · Vol 20, pp. 574-579 · 0 citations · 17 references

TL;DR

In this illustrative dataset, digital impressions demonstrated lower RMS, linear, and angular deviations relative to the reference model compared with conventional impressions, suggesting a trend towards higher overall accuracy for the digital workflow.

Abstract

Background: The passive fit of a definitive framework is a critical determinant of the long-term mechanical stability and biological health of a full-arch implant-supported prosthesis. Discrepancies at the implant–abutment or framework interface, even at the micron level, can generate residual stress within the prosthetic components and surrounding bone, potentially contributing to screw loosening, framework fracture, or marginal bone loss. As digital workflows increasingly replace conventional impression techniques in implant prosthodontics, it is important to establish whether intraoral scanning can reproducibly match or exceed the accuracy achieved with conventional splinted impressions across multiple-implant configurations. Materials and Methods: A standardized reference model incorporating six parallel implant analogues was used to simulate a full-arch edentulous arch. We performed ten illustrative repetitions for each impression technique (digital and conventional). We captured digital impressions with an intraoral scanner, while conventional impressions used a splinted open-tray technique with a rigid impression material. Result datasets/casts were superimposed onto the reference model to calculate root-mean-square (RMS) deviation, linear deviation, and angular deviation at each implant position. Passive fit was assessed via marginal microgap measurement at the framework–abutment interface using a one-screw test protocol. Results: In this illustrative dataset, digital impressions demonstrated lower RMS, linear, and angular deviations relative to the reference model compared with conventional impressions, suggesting a trend towards higher overall accuracy for the digital workflow. Conversely, the conventional impression group showed a small, statistically non-significant advantage in marginal microgap values, indicating a marginally tighter passive fit at the framework interface. No consistent pattern favouring one technique across all outcome measures was observed. Conclusion: The reported numerical results are illustrative only, intended to demonstrate the requested structured-abstract reporting format, and must not be interpreted as findings from an actual study.

Read PDF

Similar papers

Aug 2026

In Vivo Assessment of Complete-Arch Implant Impressions Using a Clinical Seating Score: A Proof-of-Principle Case Report.

The CSS may potentially provide a simple and standardized chairside method for evaluating the passive seating of complete-arch implant frameworks and help clinicians identify clinically relevant misfits before delivery of the definitive prosthesis and support more predictable decision-making during framework verificati...

Francesco Mintrone, F. Ferri, Rostyslav Havryltsiv et al. · 0 citations
Sep 2026

Evaluation of Digital Versus Conventional Workflows for Full-Arch Implant-Supported Zirconia Prostheses: A Clinical and In Vitro Study

The findings suggest that digital integration may provide a more efficient and predictable approach to full-arch implant-supported rehabilitation, although larger multicenter studies with extended follow-up are required to confirm its long-term clinical benefits.

Md. Rabiul Islam · 0 citations
#software testing Open access Sep 2026

Influence of arch form on the accuracy of digital workflow in all-on-four implant rehabilitation cases (an in vitro study)

Variations in arch form may influence the accuracy of digital impressions for implant-retained fixed dental prostheses. Differences in arch width, curvature, and span length can affect scanning continuity and data stitching, potentially impacting trueness and precision during full-arch acquisition. However, the extent...

M. S. Torky, Rewaa G. AboElhassan, Amir S. Azer · 0 citations
Review Open access Sep 2026

The Verification Jig in Multiple Implant-Supported Prostheses within the Digital Workflow: A Scoping Review

Passive fit is a mandatory prerequisite for the long-term mechanical stability of implant-supported full-arch prostheses, yet accurately transferring the three-dimensional implant position to the working cast or digital file remains the central technical challenge in this field. This scoping review, registered a priori...

Johnathan de Souza Miranda, Giovani Flach, M. Pinós et al. · 0 citations
Open access Aug 2026

The effect of build angle and intraarch connector design on the accuracy and fit of additively manufactured complete-arch implant-supported interim fixed prostheses.

Within the limitations of this single-system in vitro study, AM complete-arch implant-supported interim fixed prostheses in a 0° no-bar configuration demonstrated accuracy comparable to SM HIPC, but the marginal gaps found in some groups were beyond clinical acceptability.

Steven Sonderegger, Pedro Molinero Mourelle, Manuel Aeschbacher et al. · 0 citations
Open access Sep 2026

Accuracy of digital and conventional implant impression techniques - A comparative clinical study

Because an incorrect transfer of 3D implant sites might result in an ill-fitting prosthetic replacement with problems including peri implantitis, screw loosening, screw fracture, prosthesis or implant fracture, precise implant impressions are crucial. Therefore, it is of interest to evaluate and compare the accuracy of...

N. J. Murshitha · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.