Aug 2026· Diagnostics· Vol 16, pp. 2537· 0 citations· 30 references
Medicine
TL;DR
A precision-driven difference separated the platforms as implemented here, yet decomposing Sigma localised precision limits, isolated calibration outliers, and produced analyte-specific SQC strategies needing prospective validation.
Abstract
Background: The Six Sigma metric benchmarks analytical performance, but most reports assess one platform at one time point, merging trueness with imprecision. Using routine peer-group internal quality control (IQC), we profiled two clinical chemistry platforms over five months. Because peer-group IQC compares imprecision directly but positions trueness only against same-method peers, we characterise rather than rank cross-platform trueness. Methods: Bio-Rad Unity peer-group IQC (January–May 2026) spanned two Siemens Dimension EXL analysers and two Roche cobas pro channels, two QC levels, and 30 analytes. TEa followed the CLIA 2024 Final Rule (25 analytes; provisional EFLM goals for five non-CLIA analytes). The Standard Deviation Index (SDI) referenced trueness to same-method peers, the CV ratio (CVR) imprecision, Sigma = (TEa − |bias|)/CV. Analyte-level comparison used Wilcoxon signed-rank testing, a confirmatory mixed-effects model, and Westgard SQC mapping. Results: Across 25 CLIA-regulated analytes, median Sigma was 5.9 (IQR 4.8–8.2) for cobas pro versus 4.0 (2.3–6.1) for Dimension EXL: a Hodges–Lehmann difference of 2.4 (95% CI 1.7–3.2; p < 0.001), confirmed by CLIA-only (2.51) and mixed-effects (2.7) analyses. Both aligned with their peers (SDI near zero); the gap reflected imprecision (median CV 1.7% vs. 2.5%; CVR 0.83 vs. 1.02), stable across months and instruments. The ranking reversed for iron, GGT and amylase; sodium, chloride, urea and creatinine were TEa-limited. The SQC redesign averaged N = 6 versus N = 3 controls/run (Dimension vs. cobas pro). Conclusions: A precision-driven difference separated the platforms as implemented here. Cross-platform trueness could not be ranked, yet decomposing Sigma localised precision limits, isolated calibration outliers, and produced analyte-specific SQC strategies needing prospective validation.
Risk-based internal quality control (IQC) has been increasingly adopted in clinical laboratories to enhance analytical quality and patient safety. ISO 15189:2022 recommends designing IQC plans based on risk assessment rather than applying fixed QC frequencies. Sigma metrics combined with the QC Constellation tool...
Background/Objectives: Patient-based real-time quality control (PBRTQC) complements traditional internal quality control. This study validates a ratio-based PBRTQC integrating department clustering with inter-instrument ratio monitoring. Methods: Creatinine data (384,730 cases, 2025) from three measuring systems (A, B,...
Xue-Mei Wei, Zi-Qing Jiang, Jing-Zhu Nan et al.· Diagnostics· 0 citations
The scientific literature contains sparse data on analytical method performance, especially across multiple sites There is little publicly available information about broad analytical performance of methods or instruments. To get a better understanding of assay performance, we collected routine long-term performa...
BACKGROUND
In recent years, the error rate in the analytical stage of laboratory testing has been drastically reduced due to automation, good-quality reagents, standardized assays, and increased participation of laboratories in proficiency testing programs. Nevertheless, high error rates in extra-analytical phase remai...
J. Sharma, Roopali Rajput, Himanshu Sharma et al.· Annals of Clinical Biochemis...· 0 citations
BACKGROUND
The degree to which one is certain of results for a particular measurement/testing process is expressed as a confidence level within a range. Measurement uncertainty (MU) is a critical parameter in clinical chemistry, reflecting the degree of confidence in laboratory test results and directly influencing dia...
M. I. Ahmad, F. Ahmed, Deepa Rao et al.· Clinical Laboratory· 0 citations
The College of American Pathologists (CAP) recommends estimating measurement uncertainty (MU) during validation (typically by analyzing replicates of quality control [QC] material over 5 days); and re-evaluating MU estimates in response to a clinical inquiry (typically by a top-down approach using extended length...
Vivek Kumar, A. Gallegos· Clinical Chemistry· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.