Skip to content

Iranian Journal of Medical Physics

· 0 citations · 32 references

TL;DR

The evaluated five DCAs include Monte Carlo algorithm employed by Monaco, pencil beam convolution and anisotropic analytical algorithms employed by Eclipse and Superposition, and Clarkson algorithms employed by PCRT3D TPSs had different levels of accuracy in TPSs.

View source

Similar papers

Open access Sep 2026

Discrepancy between collapsed cone and Monte Carlo algorithms in lung inhomogeneity correction

Evaluated the accuracy of collapsed cone (CC) algorithm for dose calculation in the presence of lung inhomogeneity compared to the Monte Carlo (MC) algorithm as the reference and recommended increasing the minimum segment width to >0.5 cm in IMRT plans if CC algorithm is used.

A. Karimi, Indra J. Das, Saeedeh Moharramkhani et al. · 0 citations

Physics in Medicine & Biology

The proposed framework improves dose prediction while incorporating physically meaningful priors into the learning process, offering a promising basis for PET-based dose-monitoring model development in CIRT.

Yan Li, Wei-Guang Li, Xin-Yu Hu et al. · 0 citations
Sep 2026

Optimization of the Patient Phantom and GEANT4 Parameters in the Ion Beam Therapy Planning System

Purpose: To develop and describe the architecture of a physical module for a Dose-Anatomical Planning System (DAPS) for ion beam therapy based on the GEANT4 platform, and to optimize its computational efficiency for clinical application under limited computing resources. Material and methods: Simulation of the interac...

M. A. Makarova, O. Yushchenko · 0 citations
Sep 2026

Physics in Medicine & Biology

This work establishes a robust, cross-validated computational baseline for brachytherapy dosimetry using general-purpose MC codes under realistic photon emission spectra under realistic, unsimplified photon emission spectra.

Lucas F Ara ´ ujo, Asif Amin, Adriano Sabino et al. · 0 citations
Sep 2026

Dosimetric comparison of HDR Co-60 and Ir-192 brachytherapy sources by model-based dose calculation algorithms and its clinical implication in different brachytherapy sites and techniques.

INTRODUCTION Numerous dosimetric studies have reported clinically insignificant differences between iridium-192 and cobalt-60. However, such comparison studies were conducted using TG-43 algorithms where heterogeneity is not accounted. Model based dose calculation algorithms (MBDCA) significantly improve dosimetric acc...

Raghavendra Hajare, Rohit Avinash Vadgaonkar, Taushiful Hoque et al. · 0 citations
Open access Aug 2026

Comparison of Gonadal Dose Estimation Using Treatment Planning Systems and Monte Carlo Methods in Pelvic Radiotherapy.

INTRODUCTION Unintended irradiation of organs outside the target volume remains a concern in pelvic radiotherapy, particularly for radiosensitive structures such as the gonads. Analytical dose calculation algorithms used in treatment planning systems (TPS) may underestimate out-of-field doses. Monte Carlo (MC) methods...

D. Ribeiro, G. Campos, E. Carolino et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.