Skip to content
Open access

Image Quality of 1.5 T MRI Using Dual-Type Deep Learning Reconstruction for Pancreatic Cystic Lesions: An Exploratory Comparison With Conventional 3 T MRI Without Deep Learning Reconstruction.

Aug 2026 · Journal of Magnetic Resonance Imaging · 0 citations · 11 references
Medicine

TL;DR

In this exploratory, non-simultaneous comparison, 1.5 T DLR showed favorable image-quality metrics relative to 3 T CS without DLR, indicating a trade-off between image enhancement and naturalness.

Abstract

Background

Dual-type deep learning reconstruction (DLR) may improve the pancreatic MRI image quality; however, the effects of different DLR strengths at 1.5 T compared with the conventional 1.5 T and 3 T MRI without DLR remain unclear.

Purpose

To evaluate the image quality of 1.5 T MRI reconstructed with different DLR strengths for pancreatic cystic lesions, compared with conventional 1.5 T and 3 T MRI without DLR. STUDY TYPE Retrospective, single-center study. POPULATION Ninety-nine patients with pancreatic cystic lesion (53 men, 46 women; age range, 29.2-93.8 years) underwent 1.5 T MRI; 54 had undergone 3 T MRI within the preceding 2 years. FIELD STRENGTH/SEQUENCE 1.5 T and 3 T MRI; axial single-shot turbo spin-echo T2-weighted imaging and heavily T2-weighted single-shot turbo spin-echo two-dimensional MRCP. The 1.5 T images were reconstructed using dual-type DLR with 80% and 50% denoising levels and compressed sensing (CS) without DLR. The 3 T images used CS without DLR. ASSESSMENT Three blinded radiologists independently assessed eight image-quality items using a 5-point Likert scale. Signal-to-noise ratio, contrast-to-noise ratio, and edge rise distance were measured. STATISTICAL TESTS Friedman tests followed by Wilcoxon signed-rank tests with Holm correction were used.

Results

At 1.5 T, 80% DLR yielded significantly higher scores than CS for all qualitative items except for texture naturalness with higher SNR (40.20 vs. 23.23) and CNR (24.67 vs. 13.57) and lower ERD (1.59 vs. 1.98 mm). ERD did not differ between 80% and 50% DLR (p = 0.825). Compared with 3 T CS, 1.5 T 80% DLR showed significantly higher scores for seven of eight items, significantly higher SNR and CNR, and lower ERD (39.69 vs. 30.62; CNR, 24.33 vs. 16.17; and 1.49 vs. 2.16 mm, respectively). Texture naturalness was significantly lower with 80% DLR, indicating a trade-off between image enhancement and naturalness. DATA

Conclusion

In this exploratory, non-simultaneous comparison, 1.5 T DLR showed favorable image-quality metrics relative to 3 T CS without DLR. EVIDENCE LEVEL 3. TECHNICAL EFFICACY Stage 1.

Read PDF

Similar papers

Sep 2026

Super-Resolution Deep Learning Reconstruction for 3-Dimensional T1-Weighted Gradient-Echo Imaging in Contrast-Enhanced Liver MRI: Comparison With Conventional and Standard Deep Learning Reconstructions.

PURPOSE To evaluate the image quality of super-resolution deep learning reconstruction (SR-DLR) for 3-dimensional (3D) T1-weighted gradient-echo (GRE) imaging in contrast-enhanced MRI, compared with conventional reconstruction (Conv.) and standard deep learning reconstruction (DLR). MATERIALS AND METHODS This retrosp...

Kentaro Nishiuchi, K. Sofue, K. Tsukamoto et al. · 0 citations
Open access Sep 2026

Evaluation of Intracranial Lesions Using Deep Learning-Based Reconstruction in Canine Brain MRI: Comparison With Conventional Reconstruction on T2-Weighted and FLAIR Sequences.

Obtaining high-resolution brain MRI in small animals is challenging due to the inherent trade-off between image quality and acquisition time. Deep learning-based reconstruction (DLR) has emerged as a solution to improve image quality without prolonging scan time; however, its clinical utility and potential risks, such...

Wooseok Jin, Hye-Ran Na, Sang-Kwon Lee et al. · 0 citations
Open access Sep 2026

5.0 T versus 1.5 T and 3.0 T upper abdominal MRI: a prospective two‑cohort study of image quality and diagnostic confidence.

5.0 T upper abdominal MRI, with a primary focus on liver imaging, is clinically feasible, offering superior anatomical detail, SNR, overall image quality, and diagnostic confidence over 1.5 T and 3.0 T, supporting its clinical utility despite increased artifacts that require further optimization.

Liu-Hong Zhu, D. Lian, Fu-Nan Wang et al. · 0 citations
Open access Sep 2026

Comparison of Deep-Learning-Based Reconstruction of Knee MRI with Conventional Sequences in Patients with Knee Pain

Comparing image quality and diagnostic performance among conventional sequences and an automated accelerated deep learning-based reconstruction (DLR) knee algorithm method in patients with knee pain revealed no significant differences in overall diagnosis, image quality, and artifacts.

Rola Husain, Stephen Belmustakov, Etan Dayan et al. · 0 citations
#diffusion models Open access Sep 2026

Associations of Anatomical Location and Reader Experience With the Diagnostic Performance of Multiparametric MRI-Derived VI-RADS for Muscle Invasive Bladder Cancer: A Multicenter Multireader Study.

BACKGROUND The associations of tumor location and reader experience with Vesical Imaging-Reporting and Data System (VI-RADS) performance remain unclear. PURPOSE To evaluate the associations of tumor location and reader experience with VI-RADS performance in detecting muscle-invasive bladder cancer (MIBC). STUDY TYP...

Xiang-Yu Wang, Feng Sun, Jing-Jun Hu et al. · 1 citation

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.