Findings provide evidence that the theta attenuation of the scene construction network can be recovered at the group level with OPM-MEG, without an individual MRI.
Abstract
Optically pumped magnetometer magnetoencephalography (OPM-MEG) offers a wearable, movement-tolerant alternative to conventional cryogenic MEG, placing sensors closer to the scalp and, in principle, improving sensitivity to deep sources. This is advantageous for examining subcortical structures that are affected by ageing, disorders and disease, such as the hippocampus. However, it remains unclear whether well-established activity (such as the attenuation of theta oscillations during the imagination of novel scenes) can be recovered from the medial temporal lobe (MTL) with OPM-MEG, and whether an individual structural MRI is required. Here, fifteen adults completed a scene imagination task. Initially we applied a 12-parameter template warping coregistration pipeline to the full sample. Following source reconstruction, we recovered the expected attenuation of theta (4-8 Hz) power during scene imagination compared to a counting baseline, with a significant cluster of activity peaking in the left parahippocampal gyrus. The cluster’s centre of mass was localised to the left hippocampus (t = -3.55, p = 0.048, whole-brain FWE-corrected) and was mostly confined to the left medial temporal lobe. We further supported our findings by using an individual T1-weighted MRI reconstruction pipeline in six participants who had these scans available. The two approaches produced similar whole-brain topographies and localised the peak MTL theta effect to left hippocampus, with temporal-lobe conjunction centroids 3-mm apart. These findings provide evidence that the theta attenuation of the scene construction network can be recovered at the group level with OPM-MEG, without an individual MRI.
It is argued that OPM-MEG is developing along two partly overlapping trajectories, one of which is clinical translation and the other is naturalistic neuroscience, where wearable measurement can connect neural dynamics to movement, action, and social behaviour without conflating neural activity with movement-related ar...
Lang Qin, Miao Cao, Zhen Yuan et al.· Imaging Neuroscience· 0 citations
Non-invasive, whole-brain neuroimaging methods such as functional magnetic resonance imaging, electroencephalography (EEG), and magnetoencephalography (MEG) are essential tools for studying the basis of human cognition in health and disease. MEG offers the opportunity to study neural activity at its intrinsic timescale...
C. Gohil, George C. O'Neill, Gareth R. Barnes et al.· bioRxiv· 1 citation
Magnetoencephalography (MEG) is an imaging technique that offers a non-invasive, millisecond-resolution view of human brain activity. The increasing availability of MEG data presents an opportunity to take advantage of a recent advance in artificial intelligence, namely self-supervised foundation models. Existing found...
C. Gohil, Sungjun Cho, Oiwi Parker Jones et al.· 0 citations
This perspective lays down the basic concepts needed to understand MEG foundation models and provides a didactic overview of the field's key design choices, including tokenization, sensor- versus source-space representations, sensor-geometry encoding, backbone architectures, self-supervised objectives, and pretraining...
Philipp Thölke, Hamza Abdelhedi, Yorguin-José Mantilla-Ramos et al.· 1 citation
OBJECTIVE
Magnetoencephalography (MEG) measures magnetic fields generated by current flow in neural assemblies, providing a non-invasive means to track brain function. In recent years, the MEG field has been revolutionised by a new class of field sensor called an Optically Pumped Magnetometer (OPM). OPMs are small, li...
Lukas Rier, N. Holmes, Ryan M. Hill et al.· Physics in Medicine and Biol...· 0 citations
Wearable magnetoencephalography (MEG) enabled by optically pumped magnetometers (OPMs) promises improved comfort and motion tolerance. This is particularly beneficial when measuring brain activity in children who cannot sit still for long periods of time. Compared to cryogenic MEG, wearable MEG allows larger head movem...
M. Jas, Teppei Matsubara, Steven M. Stufflebeam et al.· bioRxiv· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.