Conspicuity and characterization of pre-selected hypodense hepatic lesions in pancreatic cancer patients: limited clinical value of dual-energy portal phase CT.
50-keV VMIs improve objective conspicuity but not subjective conspicuity, diagnostic confidence, or characterization performance, and iodine metrics provide complementary information but cannot distinguish metastases from non-cystic benign lesions.
Abstract
Purpose
To assess the impact of 50-keV virtual monoenergetic images (VMIs) and iodine metrics on conspicuity and characterization of hypodense hepatic lesions in pancreatic ductal adenocarcinoma (PDAC) patients undergoing dual-energy portal phase CT.
Methods
Consecutive patients with hypodense hepatic lesions who underwent dual-energy portal phase CT between January and December 2025 were retrospectively identified. Lesions were pre-selected by a resident. Two radiologists independently evaluated blended and 50-keV VMIs for lesion conspicuity and confidence for metastasis using 5-point Likert scales. Contrast-to-noise ratio (CNR) and iodine metrics were calculated. Subjective scores and CNRs were compared using the Wilcoxon test. Diagnostic performance for characterization was assessed using histopathology and/or imaging as the reference standard. Iodine metrics were compared using non-parametric tests. Subgroup analyses included lesions ≤ 10 mm and those in steatotic livers.
Results
181 lesions in 86 patients were included (58% metastases). Interobserver agreement was good/very good, except for diagnostic confidence in steatotic livers (k = 0.58/0.48). No differences were found between image sets in subjective conspicuity, diagnostic confidence, or characterization performance. Metastases had higher CNR on 50-keV VMIs than on blended images in the overall cohort (9.9 ± 5.7 vs. 8.5 ± 5.3, p < 0.001) and for lesions ≤ 10 mm (9.5 ± 5.1 vs. 8 ± 4, p = 0.003), but not in steatotic livers. Iodine metrics were higher in metastases than in cysts, with substantial overlap with non-cystic benign lesions.
Conclusion
50-keV VMIs improve objective conspicuity but not subjective conspicuity, diagnostic confidence, or characterization performance. Iodine metrics provide complementary information but cannot distinguish metastases from non-cystic benign lesions.
DLSCT showed high concordance with MRI for several locoregional imaging features of rectal cancer, and may provide complementary information, particularly when MRI is contraindicated or inconclusive, but these findings do not establish equivalence to MRI or diagnostic accuracy against histopathology.
S. Mazziotti, Giorgio Ascenti, Tommaso D'Angelo et al.· Diagnostics· 0 citations
OBJECTIVES
To evaluate the diagnostic performance of spectral imaging for differentiating intrapancreatic accessory spleen (IPAS) from hypervascular pancreatic neoplasms using portal-venous phase (PVP) spectral CT.
MATERIALS AND METHODS
This retrospective study included patients with hypervascular pancreatic lesions...
Y. Nagayama, Taihei Inoue, Soichiro Ishiuchi et al.· European Radiology· 0 citations
Attenuation change utilizing VUE images and iodine quantification can differentiate enhancing from nonenhancing hyperdense adnexal lesions at PCCT with excellent diagnostic performance.
Danielle Rigau, Daniel Parrott, Bhavik Bansal et al.· Abdominal Radiology· 0 citations
In this article, we assess histologically validated quantitative parameters on 18F-piflufolastat (18F-DCFPyL) prostate-specific membrane antigen (PSMA) PET and identify thresholds for differentiating malignant prostate cancer from benign tissue. Methods: In this multicenter retrospective study, men with prostate cancer...
L. Lindenberg, Erich P. Huang, G. Ulaner et al.· Journal of Nuclear Medicine· 0 citations
Purpose To investigate the utility of the intracellular enhancement (ICE) technique that suppresses extracellular signal component for shortening the gadoxetic acid (EOB)-enhanced hepatobiliary-phase (HBP) delay time while maintaining lesion visibility. Methods In this prospective study, patients who underwent EOB-enha...
Shogo Maeda, Yuko Nakamura, Toru Higaki et al.· European Journal of Radiolog...· 0 citations
In patients with bladder cancer undergoing PCD CT, diagnostic performance for muscle invasion was greater for 40-keV VMIs than for conventional polychromatic images.
Wei Wang, Jiangkai He, Jing-Yun Wu et al.· AJR. American journal of roe...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.