Sep 2026· Journal of Field Robotics· 0 citations· 31 references
TL;DR
The results demonstrate that the reconfigurable parallel mechanism meets the motion requirements of ankle rehabilitation and exhibits excellent kinematic performance within its rehabilitation range.
Abstract
This study proposes a multimode reconfigurable parallel ankle‐rehabilitation mechanism to solve the problem that the current ankle‐rehabilitation mechanism rehabilitation mode is single and difficult to meet the diverse needs of patients at different stages of recovery. The mechanism achieves variable degrees of freedom (DOFs) by adjusting the positional relationship among the drive joint axes to accommodate different rehabilitation motion modes. Screw theory was employed to analyze the mechanism's motion characteristics across various configurations. A closed‐loop vector method was adopted to establish the inverse kinematics model, and the correctness of the positional inverse solution was verified. Taking the one translational and two rotational DOFs and three rotational DOFs modes as examples, the workspace and motion/force transmission performance of the mechanism in these two modes were analyzed. The structural dimensional parameters of the mechanism were optimized using the spatial model method, yielding a performance distribution map. On the basis of this analysis, the optimal dimensional region was determined, leading to enhanced kinematic performance. The results demonstrate that the reconfigurable parallel mechanism meets the motion requirements of ankle rehabilitation and exhibits excellent kinematic performance within its rehabilitation range.
To address the problems of limited rehabilitation resources, difficulty in ensuring sufficient training intensity, and insufficient individualized training schemes for stroke patients with ankle dysfunction, this paper proposes a two-degree-of- freedom independently driven serial ankle rehabilitation robot based on the...
Yao Dai, Qing Tao, Chen-Yao Liu et al.· International Conference on...· 0 citations
Background/Objectives: Ankle rehabilitation robotics has garnered a lot of interest because of its ability to improve therapeutic outcomes and enable quantitative patient monitoring. The ankle has a complex biomechanical system, so the design needs to have accurate kinematics, structural stiffness, and biomechanical co...
To enhance the compliance and environmental adaptability of rehabilitation robots in complex human-robot interaction scenarios, a hybrid passive-active variable stiffness mechanism incorporating linear springs was designed. Based on this mechanism, a flexible cable-driven upper limb rehabilitation system was developed,...
Xiang-Xu Qu, Xiao-Jie Lv, Guan-Li Fang et al.· Journal of Physics, Conferen...· 0 citations
This work presented a biomechanically informed model and analysis of a 5-degree-of-freedom shoulder exoskeleton, constructed on a spatial parallel mechanism with a universal-prismatic-spherical joint configuration. The primary aim of the shoulder exoskeleton mechanism was to ensure the human shoulder’s natural moveme...
A. Rout, Ekta Singla· Robotica (Cambridge. Print)· 0 citations
The energy-storing and releasing (ESAR) prosthetic foot permits capturing the elastic energy and then returning it as forward propulsion. Although ESAR has been widely accepted by the majority of amputees, the selection of an alternative prosthetic for a certain user is always related to clinical feedback rather than e...
M. Hameed· Al-Qadisiyah Journal for Eng...· 0 citations