From Iodine Maps to Brain Window Images: Quantitative Visibility Thresholds of Iodine Staining Using Photon-Counting CT—A Retrospective Observational Study
Objectives: We aimed to determine quantitative photon-counting CT (PCCT)-derived iodine map (IM) attenuation associated with visual detectability of parenchymal hyperattenuation on conventional brain window (BW) images after mechanical thrombectomy (MT) and to assess corresponding relative BW attenuation changes. Methods: In this retrospective single-center study, 12 patients with anterior circulation large vessel occlusion underwent MT followed by post-interventional PCCT. BW, IM, and virtual non-contrast reconstructions were generated. Follow-up non-contrast CT served as reference for final infarction extent. Of 54 ASPECTS regions with final infarction, 40 showed IM hyperattenuation and were included in the detectability analysis. Two blinded readers assessed visual detectability. IM attenuation and relative BW attenuation increase (%ΔHU) were evaluated using ROC analysis with clustered bootstrap resampling. Thresholds were determined using the Youden index. Results: Across all 54 regions with final infarction, median IM attenuation was significantly higher in infarcted than contralateral regions (6.39 vs. 2.18 HU, p < 0.001), while absolute BW attenuation did not differ significantly. Among the 40 regions with IM hyperattenuation, 15 were visually detectable on BW images. ROC analysis showed excellent performance for IM (AUC = 0.997) and %ΔHU (AUC = 0.984). The optimal IM threshold in the original cohort was 8.33 HU (sensitivity 100%, specificity 96.0%), and the optimal %ΔHU threshold was 3.06% (sensitivity 100%, specificity 92.0%). Bootstrap-derived median thresholds were 11.69 HU (95% interval 8.33–12.67) for IM and 3.06% (3.06–20.16%) for %ΔHU. Inter-reader agreement was excellent (κ = 0.81–0.86). Conclusions: PCCT-derived iodine quantification enables objective assessment of visual detectability of post-interventional parenchymal hyperattenuation. In this cohort, an internally derived IM cutoff of 8.33 HU was associated with BW visibility. These preliminary findings require validation in larger, independent multicenter cohorts.
Background/Objectives: Characterization of small liver lesions on computed tomography (CT) remains challenging. This study evaluated whether spectral detector CT (SDCT) improves subjective diagnostic confidence in the characterization of focal hypoperfused liver lesions using additional spectral information and assesse...
M. Weisthoff, M. A. Spurek, K. Rau et al.· Diagnostics· 0 citations
Photon-counting detector CT (PCD-CT) acquires spectral data at every scan, enabling iodine map reconstruction without dedicated dual-energy protocols. This scoping review mapped the extent, characteristics, and findings of early clinical studies. Following the Joanna Briggs Institute framework and PRISMA-ScR reporting,...
A. M. Rendón-Garavito, I. E. Martínez Safar, Daniel A. Martínez D et al.· European Radiology Cardiovas...· 0 citations
Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retr...
A. Nica, C. Booz, G. Bucolo et al.· Diagnostics· 0 citations
The purpose of this work was to evaluate image quality of non-contrast neurological CT scans on a commercially available energy-integrating detector (EID) CT compared to a prototype deep silicon (dSi) photon-counting detector CT (PCCT). A cohort of subjects scanned on the EID-CT (Apex CT, GE HealthCare, Waukesha, WI) w...
A. Salyapongse, G. Avey, J. Fink et al.· AJNR. American journal of ne...· 0 citations
Background/Objectives: To evaluate, in an exploratory pilot study, the influence of slice thickness and monoenergetic (ME) level on quantitative and qualitative image quality of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) in rectal cancer (RC). Methods: This prospective pilot study enrolled 21 pati...
A. Herold, A. Strassl, Daniela Beitzke et al.· Diagnostics· 0 citations
To assess the feasibility of one-stop multi-energy dynamic volume perfusion photon-counting CT (VP-PCCT) for hepatocellular carcinoma (HCC) evaluation, including lesion detection and correlations with histopathology. From July 2024 to June 2025, 407 participants with suspected malignant liver lesions prospectively unde...
Hui-Min Lin, Jia-Hao Zhou, Rong Deng et al.· Insights into Imaging· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.