Sources of the N15 TMS-evoked potential following motor cortex stimulation localize rostrals to TMS-induced electric fields and depend on dose

Sep 2026 · Imaging neuroscience · Vol 4 · 0 citations · 73 references
Medicine

TL;DR

A spatial mismatch between early TMS-evoked potentials following motor cortex stimulation and the cortical regions exposed to peak electric fields is demonstrated, demonstrating a spatial mismatch between early TMS-evoked potentials following motor cortex stimulation and the cortical regions exposed to peak electric fields.

Abstract

Abstract Transcranial magnetic stimulation (TMS) elicits characteristic cortical responses known as TMS-evoked potentials (TEPs) measured via electroencephalography (EEG). An early negative peak can be consistently evoked over the motor cortex at around 15 ms (N15). It remains elusive whether N15 overlaps with the cortical regions receiving the highest TMS-induced electric field (E-field). We characterized the source activity of the N15 component relative to the TMS-induced E-field in 16 healthy adults who underwent TMS-EEG over the left primary motor hand area at six stimulus intensities (-8% to +12% maximum stimulator output relative to resting motor threshold) during rest and tonic contraction. Individualized head models, based on T1 and T2 MRI scans, were used for E-field simulations and source localization with LCMV, dSPM, and eLORETA as inverse solvers. Linear mixed-effects models and spatial clustering were used to assess dose- and state-dependent effects. The N15 source field was consistently located rostral to the TMS-induced electric field, with the spatial disparity decreasing as the stimulation dose increased. N15 source activity primarily clustered in the left premotor and primary motor cortex, while the TMS E-field peaked in the crowns of the pre- and postcentral gyri. All three inverse solvers yielded similar results, demonstrating consistent dose- and state-dependent effects on the N15 and suggesting that solver choice had minimal impact. These findings demonstrate a spatial mismatch between early TMS-evoked potentials following motor cortex stimulation and the cortical regions exposed to peak electric fields. Combined with prior literature, our findings provide evidence that the rostral N15 source activity reflects transsynaptic propagation via direct cortico-cortical or indirect cortico-subcortico-cortical pathways.

Read PDF

Similar papers

Open access Sep 2026

Does Pre-Sensorimotor Brain Activity Modulate TMS-Evoked Potentials?

An exploratory trial-by-trial analysis revealed an overall effect of trial-by-trial brain state on TEP amplitudes, confirming successful engagement of the sensorimotor network.

Motahare Delbari, Christoph S. Herrmann, Christian Grefkes et al. · 0 citations
Open access Nov 2026

Multidimensional Electrophysiological Responses to TMS on the Primary Motor Cortex: A TMS-EEG Characterization of Immediate Cortical Responses

A protocol-specific multidimensional electrophysiological profiles across temporal and spectral measures is demonstrated that facilitates systematic comparison across stimulation protocols and provides a basis for further investigation of TMS-induced cortical responses and individualized neuromodulation.

Yu-Yao He, Wei Wang, De-Chen Kong et al. · 0 citations
Open access Sep 2026

Timing-dependent inhibitory effects of peripheral somatosensory inputs on the primary motor cortex: A transcranial magnetic stimulation-electroencephalography study

Short-latency afferent inhibition (SAI) is a transient suppression of corticomotor excitability elicited by peripheral electrical stimulation (ES). When the interstimulus interval (ISI) between ES and transcranial magnetic stimulation (TMS) was set to 2 or 5 ms after the estimated arrival of somatosensory input in the...

Tomoya Kokue, Ryoki Sasaki, Kenichi Sugawara · 0 citations
Open access Oct 2026

Immediate cortical responses to transcranial magnetic stimulation of the human motor leg area

Background Immediate transcranial evoked potentials (iTEPs) are ultra-early electroencephalographic responses elicited by single-pulse transcranial magnetic stimulation (TMS) of the primary motor cortical hand area (M1-HAND). Their characteristic latency, waveform, and sensitivity to short-interval intracortical inhibi...

M. Beck, Marten Nuyts, Laura Sakalauskaitė et al. · 0 citations
Open access Oct 2026

Movement-specific effects of transcranial magnetic stimulation over premotor and parietal cortices after stroke

Background: Transcranial magnetic stimulation (TMS) has been proposed to support post-stroke motor recovery, but the response may depend on the task and motor-network status. We aimed to compare how premotor and parietal stimulation affects performance across reach directions with different movement demands, in prepara...

G. Haddadshargh, R. D. de Freitas, J. Mak et al. · 0 citations
Open access Oct 2026

Brain-State-Resolved Consistency of Corticospinal Responses to TMS.

BACKGROUND An important feature of motor-evoked potential (MEP) responses to transcranial magnetic stimulation (TMS) over the primary motor cortex (M1) is their substantial trial-to-trial variability. Ongoing brain activity at the time of TMS, such as the power and phase of the sensorimotor mu rhythm, influences MEP am...

Timo van Hattem, Juliana R. Hougland, Oskari Ahola et al. · 0 citations