This work incorporates a joint supervised and self-supervised training regime and utilize both magnitude and velocity data during supervision, and adds multiple acquisition-robust and conditioning strategies based on the acceleration factors.
Abstract
4D flow MRI measures time-resolved, three-directional blood velocity but requires long acquisition times, and its diagnostic signal is carried by the phase difference \emph{between} velocity encodings, not by image magnitude. Recent work has developed a per-encoding variational network to address image reconstruction in this field. In this work, we incorporate a joint supervised and self-supervised training regime and utilize both magnitude and velocity data during supervision. At the same time, we add multiple acquisition-robust and conditioning strategies based on the acceleration factors. On the CMRx4DFlow~2026 aortic dataset (1.5 and 3T), our model lowers RelErr by $38$--$50\%$ and AngErr by $7.0$--$8.7^\circ$ against a training-matched baseline across $R{=}10$--$50$, improving on every held-out subject at every acceleration. Our model also shows strong generalization ability to transfer on out-of-distribution data by employing the joint training scheme, with an increase of $7.2\%$ in SSIM and decrease of $38\%$ and $31\%$ in AngErr and RelErr respectively.
4D Flow MRI promises opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility faces trade-offs between resolution, acquisition time, and noise. Deep learning-based super-resolution offers a post-scan solution, but supervised approaches require paired or domain-specific data, while...
Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre et al.· 0 citations
Super-resolution and quality enhancement of 1.5\,T brain MRI are normally validated with image-fidelity metrics, although their purpose is to improve downstream analysis. We study whether enhancement improves tissue segmentation, and for which segmenters. We propose an unpaired, physics-guided training pipeline for a l...
Kavitha Viswanathan, Harsh Choudhary, A. Sethi· arXiv.org· 0 citations
Magnetic Resonance Imaging (MRI) is the most used non-invasive modality across medical specialties. Despite its usefulness in the clinic, the slow process of acquiring k-space data significantly inhibits patient throughput and adds restrictions to which patients can be seen and which pathologies are examined. In this w...
Umair Zaheen, Alishba Amir, Muhammad Azam et al.· Aposta: Revista de Ciencias...· 0 citations
Healthcare institutions routinely accumulate high-dimensional computed tomography (CT) volumes, but only a fraction can be annotated by experts. We present L2GSSL, a local-to-global self-supervised learning framework that leverages unlabeled volumes by decomposing pretraining into intra-slice and inter-slice representa...
Background and purpose: We propose PGPI4MR (prior-guided, physics-informed 4D MRI reconstruction), a deep learning method that leverages information from other respiratory phases or a setup scan, the first 30 s of the same scan, to improve 4D MRI reconstruction without extra scan time. Materials and methods: PGPI4MR is...
M. Safari, P. Parikh, Shan-Song Wang et al.· 0 citations
Four-dimensional flow magnetic resonance imaging measures blood velocity fields in three dimensions throughout the cardiac cycle and is increasingly used to assess hemodynamics. However, these measurements are limited by low signal-to-noise ratios and limited spatial resolution, which can compromise their accuracy and...
Aurélien de Turenne, Denis Kouamé· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.