Skip to content

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

Oct 2026 · International Conference on Medical Image Computing and Computer-Assisted Intervention · pp. 327-337 · 0 citations · 20 references
Computer Science

TL;DR

MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning, is proposed, and results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

Read PDF

Similar papers

#artificial intelligence Preprint Oct 2026

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascul...

Hai-Rong Ni, Jiahe Huang, Ming-Hao Guo et al. · 0 citations
Open access Oct 2026

Hybrid DeepLabV3+ With Embedded U-Net Skip Connections for Precise Brain Tumor Segmentation in MRI

Brain tumor segmentation from MRI is crucial for diagnosis, treatment planning, and patient monitoring, yet many automated segmentation models struggle to capture global contextual information while preserving fine spatial details, leading to inaccurate delineation of complex tumor boundaries and reduced clinical relia...

A. Karim, I. Purnama, Kusmanto Kusmanto et al. · 0 citations
Oct 2026

Adaptive consistency representation learning for semi-supervised 3D medical image segmentation.

Three-dimensional medical image segmentation plays a critical role in clinical diagnosis and surgical planning. Semi-supervised learning provides an effective way to reduce annotation requirements; however, heterogeneous feature perturbations may induce predictions with different levels of local disagreement, making un...

Li-Juan Yue, Bi-Yuan Li, Jin-Ying Ma et al. · 0 citations
Open access Oct 2026

Toponet: a topology-guided dual-branch framework for medical image classification

Volumetric medical image classification remains challenging due to limited robustness and interpretability, largely because modern models based on CNNs and Transformers primarily rely on appearance-driven cues and struggle to explicitly capture global anatomical topology, such as connectivity, loops, and cavities. To a...

Jin Sun, Nan Gao, Wen-Qi Tao et al. · 0 citations
Review Open access Oct 2026

A Survey on U-Net with Variants and Their Applications in Two-Dimensional Medical Image Segmentations

Medical image segmentation plays a critical role in computer-assisted diagnosis, treatment planning, surgical navigation, and quantitative medical image analysis. Among deep learning-based segmentation architectures, U-Net has become one of the most influential frameworks because of its encoder–decoder structure and sk...

Tian-Hui Wu, Shamsher Ullah, Bo-Chen Yu et al. · 0 citations
Sep 2026

Consensus approach to shape regularization in cross-modality cardiac segmentation

Inspired by traditional probabilistic atlases, PCMap is an average anatomical map generated from all initial segmentations, intended to enforce structural consistency, which increased shape regularity and reduced interslice discontinuities but did not consistently improve voxel-wise accuracy.

Hirohisa Oda, Toshiaki Akita · 0 citations

Related blog posts

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.