Oct 2026· Journal of Magnetic Resonance Imaging· 2 citations· 16 references
Medicine
Abstract
Background
Diffusion-weighted imaging (DWI) can support lesion detection and characterization in breast MRI. Therefore, DWI is increasingly being incorporated into breast MRI protocols to address some of the shortcomings of routine clinical breast MRI. However, especially high b value DWI can be prone to intensity artifacts that can affect diagnostic image assessment.
Purpose
To detect hyper- and hypointense artifacts on high b value DWI (b = 1500 s/mm2) using deep learning, employing either a binary classification (artifact presence) or a multiclass classification (artifact intensity) approach on a slice-wise dataset.
STUDY TYPE
Retrospective.
STUDY POPULATION
11,806 DWI slices were acquired from 156 examinations performed on female patients between 2022 and mid-2023. For both hyper- and hypointense artifact classification, the slices were split into test, validation, and holdout test set with 8164/1806/1836 and 8164/1820/1822 slices in these sets respectively.
FIELD STRENGTH/SEQUENCE
3 T spin-echo planar diffusion-weighted sequence with b values: 50, 750, and 1500 s/mm2.
ASSESSMENT
Three convolutional neural network (CNN) architectures (DenseNet121, ResNet18, and SEResNet50) were trained for binary classification of hyper- and hypointense artifacts on slice-wise labeled data. The best performing model (DenseNet121) was applied to an independent holdout test set and further trained separately for multiclass classification.
STATISTICAL TESTS
Performance of the networks was evaluated using accuracy, precision, recall, and areas under the receiver operating characteristic curve (AUROC) and under the precision recall curve (AUPRC). Radiologist evaluated bounding box positions on a 5-point Likert-like scale across 150 slices for validation and 200 slices for the holdout test set, derived from the network's Grad-CAM heatmaps.
Results
DenseNet121 achieved AUROCs of 0.91 and 0.95 for hyper- and hypointense artifact detection, respectively, and weighted AUROCs of 0.84 and 0.90 for multiclass classification on single-slice high b value diffusion-weighted images, achieving mean scores of 3.52 ± 0.81 for hyperintense artifacts and 3.62 ± 0.65 for hypointense artifacts.
DATA
Conclusion
Hyper- and hypointense artifact detection in slice-wise breast DWI MRI dataset (b = 1500 s/mm2) using CNNs, particularly DenseNet121, suggests potential reliability and requires further validation.
EVIDENCE LEVEL
3.
TECHNICAL EFFICACY
Stage 3.
The results are packaged in the Greenfield Startup Model (GSM), which explains the priority of startups to release the product as quickly as possible, and the need to shorten time-to-market, by speeding up the development through low-precision engineering activities.
Carmine Giardino, Nicolò Paternoster, M. Unterkalmsteiner et al.· IEEE Transactions on Softwar...· 178 citations· ⚡14
Software startup companies develop innovative, software-intensive products within limited timeframes and with few resources, searching for sustainable and scalable business models.
M. Unterkalmsteiner, P. Abrahamsson, Xiaofeng Wang et al.· e-Informatica Software Engin...· 157 citations· ⚡17
This study conducts a case survey study based on the secondary data of the major pivots happened in 49 software startups, and demonstrates that customer need pivot is the most common among all pivot types.
Sohaib Shahid Bajwa, Xiaofeng Wang, Anh Nguyen-Duc et al.· Empirical Software Engineeri...· 127 citations· ⚡15
The comparison of adopter and non-adopter sample reveals three potential adoption inhibitor, security, data privacy, and portability, which underlines the importance of the technical and security perspectives for research investigating the adoption of technology.
Nattakarn Phaphoom, Xiaofeng Wang, S. Samuel et al.· Journal of Systems and Softw...· 111 citations· ⚡8
Objective There is dearth of information on the timeliness of antenatal care (ANC) uptake. This study aimed to determine the timely ANC uptake by a medically trained provider (MTP) as per the World Health Organization (WHO) recommendations and the country guideline. Methods Cross-sectional survey was done with 2,731 wo...
B. Sarker, Musfikur Rahman, T. Rahman et al.· PLoS ONE· 89 citations· ⚡7
This study investigates how Lean internal startup facilitates software product innovation in large companies and identifies its enablers and inhibitors, and shows the potential of the method-in-action framework to investigate the Lean startup approach in non-startup context.
Henry Edison, Nina M. Smørsgård, Xiaofeng Wang et al.· Journal of Systems and Softw...· 78 citations· ⚡6