Skip to content
Open access

Comparison of Artificial Intelligence-Driven Echocardiographic Assessment of Diastolic Function With the ASE Guidelines

Sep 2026 · JACC: Advances · Vol 5, pp. 103115 · 1 citation · 34 references
Medicine

TL;DR

In settings where not all guideline-recommended parameters are available, the DL model may improve prognostic and diagnostic performance compared with both guideline versions, and require further validation to confirm that the observed advantages persist when all guideline-recommended parameters are systematically acquired.

Abstract

Background Contemporary guideline-based assessment of left ventricular diastolic function and filling pressure requires multiple echocardiographic parameters that may not be routinely acquired in real-world clinical practice. Objectives The aim of the study was to compare the prognostic and diagnostic performance of a previously validated deep learning (DL) model for left ventricular diastolic function assessment with those of the 2016 ASE (American Society of Echocardiography)/EACVI (European Association of Cardiovascular Imaging) and 2025 ASE guidelines. Methods The DL model and the guidelines were compared in the ARIC (Atherosclerosis Risk In Communities) cohort (n = 5,450) for prognostication and in 2 hemodynamic validation cohorts from the United States (n = 83) and Japan (n = 130) for diagnosing elevated left ventricular filling pressure. In all 3 cohorts, ≥1 guideline-recommended parameters were unavailable in a substantial proportion of patients. Results In the ARIC cohort, the DL model achieved a higher C-index than both the 2016 ASE/EACVI and 2025 ASE guidelines (0.676 vs 0.638 and 0.602, respectively; both P < 0.001). In the United States cohort, the DL model achieved a higher area under the receiver operating characteristic curve (AUC) than the 2025 ASE guidelines (0.879 vs 0.822; P = 0.041) and a similar AUC to the 2016 ASE/EACVI guidelines (0.879 vs 0.812; P = 0.138). In the Japanese cohort, the DL model achieved a higher AUC than both guideline versions (0.816 vs 0.694 and 0.634, respectively; both P < 0.05). Conclusions In settings where not all guideline-recommended parameters are available, the DL model may improve prognostic and diagnostic performance compared with both guideline versions. Nevertheless, these exploratory findings require further validation to confirm that the observed advantages persist when all guideline-recommended parameters are systematically acquired.

Read PDF

Similar papers

Open access Oct 2026

Grading left ventricular diastolic function and filling pressure using artificial intelligence-enabled echocardiography

Assessment of left ventricular diastolic dysfunction (LVDD) and filling pressure is standard in echocardiography but remains time- and expertise-dependent. We evaluated the performance and prognostic significance of an artificial intelligence (AI)-enabled echocardiography for LVDD grading. An AI model was...

R. Loutati, M. Fiman, A. Amshalom et al. · 0 citations
Open access Oct 2026

Development and external validation of a novel echocardiography-based AI model for predicting aortic stenosis progression

Aortic stenosis (AS) is the most common valvular heart disease in older adults and requires timely identification of patients who need intervention. Nevertheless, current surveillance strategies rely on fixed follow-up intervals that do not adequately reflect the highly variable rate of disease progression among...

K. Faierstein, E. Itelman, T. Caller et al. · 0 citations
Open access Oct 2026

AI-assisted echocardiographic assessment of left ventricular function in primary care: a prospective implementation study

Timely detection and monitoring of left ventricular (LV) dysfunction in primary care remain challenging due to limited access to comprehensive echocardiography and variable operator expertise. Although point-of-care ultrasound (POCUS) by general practitioners (GPs) may enable earlier detection, accurate estimatio...

M. Illyés, R. Kiss-Kovács, L. Szénási et al. · 0 citations
Open access Oct 2026

AI-ECG detection of diastolic dysfunction: A screening approach for early HFpEF

Left ventricular diastolic dysfunction (LVDD) is highly prevalent in the general population and represents an early stage of heart failure with preserved ejection fraction (HFpEF). Diagnosis relies on Doppler-based echocardiographic parameters, limiting its feasibility for large-scale screening. While artificial...

M. Soh, Y. Lee, H. Hong et al. · 0 citations
Oct 2026

Diastolic Function From Artificial Intelligence-Derived Electrocardiography in Mitral Annulus Calcification.

OBJECTIVE To evaluate whether a validated artificial intelligence-enabled electrocardiography (AI-ECG) model for left ventricular diastolic function (LVDF) can provide prognostic risk stratification in patients with significant mitral annulus calcification (MAC). METHODS We included patients who underwent transthorac...

G. Tsaban, E. Lee, Y. Wong et al. · 0 citations
Open access Oct 2026

Deep learning-based strain echocardiography adds prognostic value in heart failure with reduced ejection fraction

Echocardiographic global longitudinal strain (GLS) and mechanical dispersion (MD) improve risk prediction in heart failure. To facilitate clinical implementation, we aimed to develop a deep learning-based method for fast, fully automated GLS and MD and validate its ability to predict ventricular arrhythmia (VA) a...

D. Melichova, J. Nyberg, T. Nguyen et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.