CORROSION BEHAVIOUR OF REINFORCED CONCRETE IN LAGOS LAGOON: INFLUENCE OF WATER-CEMENT RATIO AND COVER DEPTH UNDER PHOTOVOLTAIC-ASSISTED IMPRESSED CURRENT TESTING
Abstract
Globally, reinforced concrete (RC) structures exposed to marine environments are highly prone to corrosion due to chloride penetration - which deteriorates steel reinforcement, concrete and their bond, reduces service life and increases maintenance costs. This study examined the corrosion behavior of RC specimens exposed to the Lagos Lagoon, emphasizing the effects of water-cement (w/c) ratio (0.48, 0.50, 0.55 and 0.60) and concrete cover (20 mm, 40 mm, 50 mm, and 75 mm) on a 40N/mm2 concrete grade specimens. Photovoltaic-assisted impressed current accelerated corrosion test and Lagos Lagoon water sample were utilized to induce corrosion on the RC specimens for a period of 35days. Corrosion rate was computed with weight loss method, while scanning electron microscopy with energy dispersive x-rays spectroscopy (SEM-EDX) was used to characterize the steel reinforcements. The results showed that, the Lagos Lagoon water was chloride-rich, with average chloride concentration of 3,050.25 mg/L. Increasing the w/c ratio from 0.48 to 0.60 increased chloride penetration and accelerated the steel rebar corrosion rate from 0.1663 to 0.4697 mm/year, whereas increasing the concrete cover from 20 to 75 mm reduced the steel rebar corrosion rate from 0.4011 to 0.2583 mm/year by lengthening chloride diffusion paths and reducing concrete permeability. Visual observations and weight loss measurements further confirmed greater steel rebar damage in RC specimens with higher w/c ratios and smaller concrete covers. The SEM-EDX confirmed cracks and corrosion product on the steel rebar’s surface retrieved from RC specimen. The study concluded that both w/c ratio and concrete cover are crucial in determining corrosion resistance of RC structures in the Lagos Lagoon environment. A concrete cover of 50-75 mm and adherence to code-specified w/c ratio limits are recommended to enhance durability. The study advocates using photovoltaic-assisted impressed current testing for laboratory corrosion analysis.