Dosimetric equivalence of deep learning prostate contours after LDR brachytherapy: pre-declared margins, patient-level acceptance thresholds and the incremental predictive value of DVH indices
The authors' DVH indices panel provides no significant predictive power for IPSS, irrespective of segmentation source and horizon, and individual equivalence requires a volume dependent quality metric threshold definition.
Abstract
Background and purpose: Dose Volume Histogram (DVH) indices remain the main dose-effect metrics for toxicity prediction, but they depend on how contours were made. Inter-observer variability (IOV) is unavoidable and clinically accepted, so the question for automatic segmentation addresses equivalence: do automatic contours produce DVH errors comparable to human IOV, and can these indices predict patient-reported toxicity? Materials and methods: In 429 patients treated with iodine-125 LDR-BT monotherapy, indices from expert manual delineation were compared with a deterministic and a Bayesian nnUNet on a fixed dose distribution, by two-one-sided tests against margins set from CT contouring IOV. Logistic regression gave patient-level thresholds at 90\,\% probability of equivalence. In 380 patients, eleven DHV indices were added to a clinical baseline predicting change in International Prostate Symptom Score (IPSS) at six horizons over 5 years, with nested cross-validation, bootstrap intervals and corrected $t$-tests. Results: All cohort-level comparisons of DVH indices were declared equivalent, with no interval consuming more than 44\,\% of its equivalence margin. Individual agreement was weaker with equivalence rates from 55.9\,\% to 89.7\,\%, depending on the DVH index and automatic segmentation model. Thresholds ranged from 0.864 to 0.958 Dice. No DVH block improved IPSS prediction at any horizon. The largest improvement declared by bootstrap intervals was 0.12 IPSS points, well below the minimal clinically important difference, across all learners. Conclusion: Automatic contours matched expert dosimetry within human IOV on average, but individual equivalence requires a volume dependent quality metric threshold definition. Our DVH indices panel provides no significant predictive power for IPSS, irrespective of segmentation source and horizon.
Residual intrafraction motion produced directionally asymmetric coverage loss, with the largest effect on the boosted GTV, and motion-inclusive dose reconstruction enabled derivation of practical asymmetric margins that improved robustness while identifying the tradeoff between target coverage and delivery efficiency.
Ka-Ho Tam, S. Jogi, A. Sobremonte et al.· medRxiv· 0 citations
Purpose Classical nomograms for high-dose-rate (HDR) prostate brachytherapy quality assurance (QA) evaluate agreement between planned and expected total dwell time but do not directly assess the three-dimensional treated volume. This study's aim was to develop a deep learning-based 3D nomogram to predict institution-sp...
Joel Beaudry, Tong-He Wang, S. Enger et al.· Physics and Imaging in Radia...· 0 citations
3D U-Net provided the most favorable overall performance among the evaluated architectures for intact-cervix cases and support further physician-supervised implementation, followed by multicenter external validation and cohort-level dosimetric assessment.
Chen-Ying Ma, Yi Fu, Lu Zhang et al.· Frontiers in Oncology· 0 citations
PURPOSE
This study evaluated the performance of three AI-based segmentation tools for breast clinical target volumes (CTV) and organs at risk (OARs): a commercial solution, an open-source tool, and an in-house UNet model. Inter-observer variability (IOV) was computed and used as a benchmark for the subsequent considera...
F. Maddaloni, S. Broggi, A. Fodor et al.· Physica medica (Testo stampa...· 0 citations
Background/Objectives: Online adaptive radiotherapy (oART) re-optimizes treatment on the anatomy of the day, but automatically generated plans require dosimetric verification and dose–volume assessment. We performed an end-to-end validation of the Varian Ethos workflow for prostate cancer, including cross-adaptation be...
DIR-based dose accumulation resulted in significantly lower HR-CTV dose estimates compared with SS, while dose differences for the bladder and rectum remained minimal, and future research should correlate DIR-based dosimetry with clinical outcomes to support anatomically adaptive brachytherapy.
Chitchaya Suwanraksa, Bheampos Rojkitjanuruk, Tanapat Suwanpan et al.· Journal of Health Science an...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.